Well Details

Well ID: 37-129-21888
Loading map...
Country: United States
State: Pennsylvania
County: Westmoreland
Municipality: Derry Township
Operator Name: SML LIMITED PATNERSHIP
Well Pad ID:
Farm/Lease Name: WAYNE RUSH ET UX 1
License Status: ACTIVE
Spud Date:
Permit Date: 1981-06-30
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.411745
Longitude: -79.398448

For data sources see[1][2][3]

Well History

Date Event
1981-06-30 New Permit Application
1981-07-07 Performed Spud Operation
1981-07-13 Drilling Completion
1981-09-14 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
1993 PHILLIPS PROD CO 0.00 0 0.00 0 0.00 0
1994 PHILLIPS PROD CO 0.00 0 0.00 0 0.00 0
1996 INTERSTATE GAS MKT INC 200 365 0.00 0 0.00 0
1997 INTERSTATE GAS MKT INC 265 365 0.00 0 0.00 0
1998 INTERSTATE GAS MKT INC 200 365 0.00 0 0.00 0
1999 INTERSTATE GAS MKT INC 200 365 0.00 0 0.00 0
2000 INTERSTATE GAS MKT INC 200 365 0.00 0 0.00 0
2001 INTERSTATE GAS MKT INC 863 122 0.00 0 0.00 0
2002 INTERSTATE GAS MKT INC 797 180 0.00 0 0.00 0
2003 INTERSTATE GAS MKT INC 446.47 210 0.00 0 0.00 0
2004 INTERSTATE GAS MKT INC 959 330 0.00 0 0.00 0
2005 INTERSTATE GAS MKT INC 404 210 0.00 0 0.00 0
2006 INTERSTATE GAS MKT INC 0.00 0 0.00 0 0.00 0
2007 INTERSTATE GAS MKT INC 0.00 0 0.00 0 0.00 0
2008 INTERSTATE GAS MKT INC 294.00 120 0.00 0 0.00 0
2009 INTERSTATE GAS MKT INC 0.00 0 0.00 0 0.00 0
2010 INTERSTATE GAS MKT INC 0.00 0 0.00 0 0.00 0
2011 SML LIMITED PATNERSHIP 90.00 365 0.00 0 0.00 0
2012 SML LIMITED PATNERSHIP 90.00 365 0.00 0 0.00 0
2013 SML LIMITED PATNERSHIP 90.00 365 0.00 0 0.00 0
2014 SML LIMITED PATNERSHIP 90.00 365 0.00 0 0.00 0
2015 SML LIMITED PATNERSHIP 90.00 365 0.00 0 1 365
2016 SML LIMITED PATNERSHIP 90.00 365 1.00 365 1 365
2017 SML LIMITED PATNERSHIP 90.00 365 1.00 365 1.00 365
2018 SML LIMITED PATNERSHIP 90.00 365 1.00 365 1.00 365

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 SML LIMITED PATNERSHIP Produced Fluid 0.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 101674
2011 SML LIMITED PATNERSHIP Produced Fluid 1.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 101674
2012 SML LIMITED PATNERSHIP Produced Fluid 1.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 101674
2013 SML LIMITED PATNERSHIP Produced Fluid 1.00 Bbl RESIDUAL WASTE TRANSFER FACILITY 101674
2014 SML LIMITED PATNERSHIP Produced Fluid 1.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273
2014 SML LIMITED PATNERSHIP Produced Fluid 1 Bbl CENT WASTE TRT FAC NPDES PA0095273
2015 SML LIMITED PATNERSHIP Produced Fluid 1.00 Bbl RESIDUAL WASTE TRANSFER FACILITY 101674
2016 SML LIMITED PATNERSHIP Produced Fluid 1.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NW003
2017 SML LIMITED PATNERSHIP Produced Fluid 2.00 Bbl RESIDUAL WASTE PROCESSING FACILITY 101674
2019 SML LIMITED PATNERSHIP Produced Fluid 1.00 Bbl RESIDUAL WASTE PROCESSING FACILITY 101674

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1085581 Primary Facility 2001-12-26 Routine/Complete Inspection No Violations Noted Tag, tank, e&s ok.
2634029 Primary Facility 2017-09-08 Complaint Inspection Violation(s) Noted At the time of inspection well equipped for production. Brine tank appears to be structurally sound, no active leaks observed during inspection. However, during inspection Department observed what appears to be remnants of an old spill, as indicated by visibly stained dirt, stressed and/or dead vegetation. No visible sheen observed, however petroleum odor present.

Additionally, at the time of inspection, no well tag present. Department identified well using GPS coordinates and well records.

Department recommends Operator perform clean-up in accordance with Spill Policy and forward copies of sampling results and remediation reports upon receipt. Department requests Operator provide a written response detailing the cause, time of spill, quantity and type of materials released, the affected media and any surrounding impacts to water supplies and/or buildings, remediation method selected and actions taken to remediate and future actions to prevent such incidents.

Department contacted Operator (Luke Latimer)

2642957 Primary Facility 2017-10-03 Compliance Evaluation No Violations Noted At the time of inspection, cleanup appears to be complete. All visually impacted area has been excavated. Well tag present and affixed in a permanent manner. No E&S issues.

Previously issued violations have been resolved.

2645825 Primary Facility 2017-09-29 Administrative/File Review No Violations Noted Department received Operator Response to inspection ID 2634029.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2634029 796039 2017-09-08 2017-10-03 OGA3211(H) Administrative No well tag present.
2634029 796040 2017-09-08 2017-10-03 78.57(a) Environmental Health & Safety At the time of inspection Department observed what appears to be remnants of an old spill as indicated by visibly stained dirt and stressed and/or dead vegetation.

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
796039 357834 NOV - Notice of Violation 2018-01-22
796040 357834 NOV - Notice of Violation 2018-01-22

For data sources see[7]