If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-129-26257 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.593685,"lon":-79.667198,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Westmoreland | |
Municipality: Allegheny Township | |
Operator Name: HARPER CROSBY HOLDINGS LLC | |
Well Pad ID: | |
Farm/Lease Name: APOLLO TRUST COMPANY 1-P027 | |
License Status: ACTIVE | |
Spud Date: | |
Permit Date: 2006-04-03 | |
Well Type: GAS | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 40.593685 | |
Longitude: -79.667198 |
Date | Event |
---|---|
2006-04-03 | New Permit Application |
2006-05-05 | Performed Spud Operation |
2006-05-08 | Drilling Completion |
2006-05-18 | Perforation |
2006-06-08 | NEWLY DRILLED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2006 | MTN V OIL & GAS INC | 5090.00 | 198 | 0.00 | 0 | 0.00 | 0 |
2007 | MTN V OIL & GAS INC | 5216.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2008 | MTN V OIL & GAS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2009 | MTN V OIL & GAS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2010 | MTN V OIL & GAS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | HAYDEN HARPER ENERGY KA LLC | 1,931.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | HAYDEN HARPER ENERGY KA LLC | 1,922.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | HAYDEN HARPER ENERGY KA LLC | 1,741.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | HARPER CROSBY HOLDINGS LLC | 1,572.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2017 | HARPER CROSBY HOLDINGS LLC | 1,582.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | HARPER CROSBY HOLDINGS LLC | 1,610.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2017 | HARPER CROSBY HOLDINGS LLC | Produced Fluid | 80.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095273 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1535982 | Primary Facility | 2006-04-18 | Routine/Complete Inspection | No Violations Noted | WELL STAKED-SITE NOT MADE/OBJECTION-NO WELAND WAIVER NEEDED |
1535984 | Primary Facility | 2006-04-25 | Routine/Complete Inspection | No Violations Noted | WELL STAKED-SITE NOT MADE/MEETING WITH OPR & PROP OWNER |
2387029 | Primary Facility | 2015-07-09 | Routine/Complete Inspection | No Violations Noted | At the time of inspection well appears equipped for production. Site permanently stabilized. No E&S issues in relation to site and/or access road. Department recommends Operator continue to perform routine maintenance of access road in order to prevent a potential pollution event and/or accelerated E&S issues from occurring. Brine tank located on site and appears structurally sound. During inspection Department noted well tag present and permanently affixed, however incorrect county identification number of 124 indicated on tag. Department recommends Operator update well tag to reflect correct county identification number of 129 and notify Department of the resolution of this issue. During inspection Department also noted what appears to be a surface collapse around the conductor casing. Unable to determine the depth of cavity due to the accumulation of water. No sheen on water visible at this time. |
For data sources see[7]