If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-129-27490 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.358548,"lon":-79.334411,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Westmoreland | |
Municipality: Derry Township | |
Operator Name: RE GAS DEV LLC | |
Well Pad ID: 147589 | |
Farm/Lease Name: ANKNEY | |
License Status: Plugged and Abandoned | |
Spud Date: 2008-08-01 | |
Permit Date: 2008-06-04 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 40.358548 | |
Longitude: -79.334411 |
Date | Event |
---|---|
2008-06-04 | New Permit Application |
2008-08-01 | Performed Spud Operation |
2008-08-20 | Drilling Completion |
2008-10-08 | Perforation |
2008-10-30 | Performed Stimulation |
2009-08-19 | NEWLY DRILLED |
2018-08-02 | Begin Plugging |
2018-09-01 | Finished Plugging |
2019-07-26 | Fully Plugged |
For data sources see[4]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2008-10-30 | Sand | 0 | 0 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2008 | REX ENERGY OPERATING CORP | 16370.00 | 61 | 0.00 | 0 | 0.00 | 0 |
2009 | REX ENERGY OPERATING CORP | 80403.23 | 365 | 0.00 | 0 | 0.00 | 0 |
2010 | REX ENERGY OPERATING CORP | 53,945.64 | 302 | 0.00 | 0 | 0.00 | 0 |
2011 | REX ENERGY OPERATING CORP | 32,408.30 | 303 | 0.00 | 0 | 0.00 | 0 |
2012 | RE GAS DEV LLC | 87,099.00 | 350 | 0.00 | 0 | 0.00 | 0 |
2013 | RE GAS DEV LLC | 26,116.32 | 181 | 0.00 | 0 | 0.00 | 0 |
2014 | RE GAS DEV LLC | 64,245.28 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | RE GAS DEV LLC | 40,495.91 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | RE GAS DEV LLC | 9,909.24 | 139 | 0.00 | 0 | 0.00 | 0 |
2017 | RE GAS DEV LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2008 | REX ENERGY OPERATING CORP | Brine | 400.00 Bbl | Brine or Industrial Waste Treatment Plt | PA0101508 |
2008 | REX ENERGY OPERATING CORP | Fracking Fluid | 810.00 Bbl | Brine or Industrial Waste Treatment Plt | PA0101508 |
2008 | REX ENERGY OPERATING CORP | Fracking Fluid | 2,890.00 Bbl | Brine or Industrial Waste Treatment Plt | PA0091472 |
2009 | REX ENERGY OPERATING CORP | Brine | 300.00 Bbl | Brine or Industrial Waste Treatment Plt | PA0101508 |
2009 | REX ENERGY OPERATING CORP | Brine | 700.00 Bbl | Brine or Industrial Waste Treatment Plt | PA0091472 |
2010 | REX ENERGY OPERATING CORP | Produced Fluid | 210.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0091472 |
2012 | REX ENERGY OPERATING CORP | Produced Fluid | 1,150.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0254185 |
2012 | REX ENERGY OPERATING CORP | Produced Fluid | 400.00 Bbl | INJECTION DISPOSAL WELL | 34-007-24523 |
2013 | RE GAS DEV LLC | Produced Fluid | 172.62 Bbl | INJECTION DISPOSAL WELL | 34-031-27177 |
2014 | RE GAS DEV LLC | Produced Fluid | 83.50 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
2015 | RE GAS DEV LLC | Produced Fluid | 35.00 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2016 | RE GAS DEV LLC | Produced Fluid | 56.50 Bbl | INJECTION DISPOSAL WELL | 34-157-25506 |
2018 | RE GAS DEV LLC | Drilling Fluid Waste | 100.00 Bbl | CENT WASTE TRT FAC NPDES | EPA ID: 748-163 |
2018 | RE GAS DEV LLC | Produced Fluid | 110.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018 | RE GAS DEV LLC | Produced Fluid | 18.04 Tons | CENT WASTE TRT FAC NPDES | EPA ID: 748-163 |
2018 | RE GAS DEV LLC | Drilling Fluid Waste | 515.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018 | RE GAS DEV LLC | Drilling Fluid Waste | 100.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | EPA ID: 748-163 |
2018 | RE GAS DEV LLC | Produced Fluid | 305.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24079 |
2018 | RE GAS DEV LLC | Drilling Fluid Waste | 90.00 Bbl | REUSE (AT WELL PAD) | |
2018 | RE GAS DEV LLC | Produced Fluid | 18.04 Tons | CENT WASTE TRT FAC NPDES DISCHARGE | EPA ID: 748-163 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1725930 | Primary Facility | 2008-08-05 | Drilling/Alteration | No Violations Noted | Spudded 8/1/08. Rig drilling @ 1501' at time of inspection. Pit/freeboard/E&S controls OK. |
1930235 | Primary Facility | 2010-11-23 | Routine/Complete Inspection | No Violations Noted | RECLAIMED, VEGETATED, AND DYKE AROUND TANK AND METER UNIT. I RECIEVED A CALL FROM REX ENERGY 11/22/2010 AROUND 7:30 PM TO INFORM ME THAT THE UNIT ON SITE CAUGHT FIRE. THE WELL WAS SHUT IN AND THE FIRE WAS PUT OUT WITHIN 20 MINUTES AFTER IGNITION BY A WELL TENDER NEAR BY. LOCAL FIRE DEPARTMENT WAS DISPATCHED. DUE TO A FAULTY VALVE THAT BROKE LEAVING GAS INTO THE HEATER UNIT CAUSING IGNINTION. |
2275798 | Primary Facility | 2014-05-30 | Routine/Complete Inspection | No Violations Noted | VERTICAL MARCELLUS |
2284539 | Primary Facility | 2014-07-08 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the well appears to be drilled and equipped for production. Well apparatus, brine tank and heater unit appear to be in sound condition. Well site appears to be restored. |
2440136 | Primary Facility | 2016-01-12 | Routine/Complete Inspection | No Violations Noted | Access road gated, locked and shared with ag field. At the time of inspection well appears equipped for production. Well tag present and affixed in a permanent manner. Brine tank located on site within secondary containment and appear to be structurally sound. Site permanently stabilized with no E& S issues in relation to site and/or access road. |
2474457 | Primary Facility | 2016-04-13 | Routine/Complete Inspection | No Violations Noted | Well tagged-in production. Well head casing-production equipment-tank and dike look ok. |
2554704 | Primary Facility | 2017-01-24 | Routine/Complete Inspection | No Violations Noted | Well tagged-shut in. A check with efacts disclosed production reported for the previous year. Well head casing-production set equipment-tank-dike containment looked ok. |
2621747 | Primary Facility | 2017-08-02 | Routine/Complete Inspection | No Violations Noted | Well tagged and shut in. Am discussing regulatory inactive status of this well with operator. Well head casing-production set equipment-tank and dike containment look ok. |
2653802 | Primary Facility | 2017-10-30 | Compliance Evaluation | No Violations Noted | This is a regulatory inactive status request inspection. The well is tagged and shut in. The well head casing, equipment, fluid collection tank and containment dike all looked ok. |
2678201 | Primary Facility | 2018-01-04 | Routine/Complete Inspection | No Violations Noted | At the time of inspection well equipped for production. Brine tank within secondary containment and appears to be structurally sound. No E&S issues. |
2756944 | Primary Facility | 2018-07-25 | Routine/Complete Inspection | No Violations Noted | Inspection in response to Operator's request for site inspection prior to commencement of plugging. At the time of inspection, well plugging had not commenced. No E&S issues. |
2761688 | Primary Facility | 2018-08-07 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Site inspection prior to plugging well |
2763589 | Primary Facility | 2018-08-14 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Brisge plug set at 8078 ft. 5 bbl cement pumped below and above plug. Pressure at 3100 psi prior to cementing. |
2765181 | Primary Facility | 2018-08-20 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | On 8/16, CIBP set at 6720 ft. Pumped 25 bbl class H and then 6bbl spacer On 8/17, ran wireline and showed top of cement at 6170 ft below grade. Came up 100 ft and cut 51/2inch. On 8/18, pulled over the 120 percent and would not move. Came up to 4010 ft, and cut again where appeared to be free on 8/19. On 8/20, Rex planning to circulate and pulled 5 1/2inch and cement plugs on 8/21. |
2765815 | Primary Facility | 2018-08-22 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Rex energy setting 1700 ft cement plug in three stages. Starting at 3838 ft. To 3271. Ft. Second plug to 2668 ft and third cement to 2065 ft. |
2768122 | Primary Facility | 2018-08-27 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Bridge plug set at 453 ft. Cement plug set at 453 ft to 253 ft. Well currently capped and allowing to be monitored for any pressure. Currently no preesure measured. Rex will finish well with monument. |
2783765 | Primary Facility | 2018-10-03 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Site secured. No field activity. Site was reclaimed. |
2789414 | Primary Facility | 2018-10-16 | Routine/Complete Inspection | No Violations Noted | At the time of inspection well plugging appears to be complete. Excavated areas stabilized and seeded and mulched. No E&S issues. |
For data sources see[8]