{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.503967,"lon":-79.560975,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Westmoreland | |
Municipality: Washington Township | |
Operator Name: CNX GAS CO LLC | |
Well Pad ID: 147700 | |
Farm/Lease Name: MAWC TR 32 AIKENS | |
License Status: Plugged and Abandoned | |
Spud Date: 2009-10-29 | |
Permit Date: 2009-10-20 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 40.503967 | |
Longitude: -79.560975 |
Date | Event |
---|---|
2009-10-20 | New Permit Application |
2009-10-27 | Performed Spud Operation |
2009-11-05 | Drilling Completion |
2009-11-12 | Perforation |
2010-08-10 | Newly Drilled |
2016-08-10 | Begin Plugging |
2016-08-31 | Finished Plugging |
2019-05-31 | Fully Plugged |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2009 | CONSOL GAS CO | 12846.07 | 365 | 0.00 | 0 | 0.00 | 0 |
2010 | CONSOL GAS CO | 73,509.00 | 305 | 0.00 | 0 | 0.00 | 0 |
2011 | CNX GAS CO LLC | 27,494.00 | 212 | 0.00 | 0 | 0.00 | 0 |
2012 | CNX GAS CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | CNX GAS CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | CNX GAS CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | CNX GAS CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | CNX GAS CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | CNX GAS CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2009 | CONSOL GAS CO | Fracking Fluid | 3,500.00 Bbl | Brine or Industrial Waste Treatment Plt | PA0091472 |
2009 | CONSOL GAS CO | Brine | 227.00 Bbl | Brine or Industrial Waste Treatment Plt | PA0091472 |
2009 | CONSOL GAS CO | Brine | 50.00 Bbl | Municipal Sewage Treatment Plant | PA0026034 |
2009 | CONSOL GAS CO | Brine | 57.00 Bbl | Injection Disposal Well | 5690201 |
2009 | CONSOL GAS CO | Brine | 977.00 Bbl | Brine or Industrial Waste Treatment Plt | PA0095273 |
2009 | CONSOL GAS CO | Fracking Fluid | 4,200.00 Bbl | Brine or Industrial Waste Treatment Plt | PA0095443 |
2010 | CONSOL GAS CO | Produced Fluid | 184.04 Bbl | PUBLIC SEWAGE TREATMENT PLANT | PA0026034 |
2010 | CONSOL GAS CO | Fracing Fluid Waste | 1,750.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0091472 |
2010 | CONSOL GAS CO | Produced Fluid | 547.86 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0095273 |
2010 | CONSOL GAS CO | Produced Fluid | 297.36 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0091472 |
2010 | CONSOL GAS CO | Produced Fluid | 89.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 3703326803 |
2010 | CONSOL GAS CO | Fracing Fluid Waste | 2,100.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0095443 |
2011 | CONSOL GAS CO | Drilling Fluid Waste | 440.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0091472 |
2011 | CNX GAS CO LLC | Produced Fluid | 120.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 34-099-23127 |
2011 | CONSOL GAS CO | Produced Fluid | 790.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0091472 |
2016 | CNX GAS CO LLC | Servicing Fluid | 2,422.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CNX GAS CO LLC | Other Oil & Gas Wastes | 19.48 Tons | LANDFILL | CID: 29084 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1841126 | Primary Facility | 2009-11-04 | Drilling/Alteration | No Violations Noted | MARCELLUS - drilling/E&S ok/ID& pit ok |
1859134 | Primary Facility | 2010-01-25 | Routine/Complete Inspection | No Violations Noted | The well has been drilled and is equipped for production. Well tag located. The brine tanks appear to be in sound condition. The site has been re-graded but is not seeded and mulched. The Site ID sign and E&S plan were located. There is no evidence of erosion & sedimentation on the site or the access road. The operator should continue to monitor the site for erosion and sedimentation until final restoration activities are completed. |
1947216 | Primary Facility | 2011-01-25 | Routine/Complete Inspection | No Violations Noted | Well is operating and properly identified. |
2162588 | Primary Facility | 2013-04-18 | Routine/Complete Inspection | No Violations Noted | Operator submitted Application for Inactive Well Status dated 03-27-13. |
2363471 | Primary Facility | 2015-04-22 | Routine/Complete Inspection | No Violations Noted | Well properly identified. Well shut-in and production lines disconnected. 8 5/8” x 5 1/2” annulus open. Regulatory Inactive Well Status dated 05-03-13. |
2476262 | Primary Facility | 2016-04-19 | Routine/Complete Inspection | No Violations Noted | Well tagged-shut in. Annulus is open. Well head casing looks ok. Checking with operator on 5 year inactive status of this well. |
2507866 | Primary Facility | 2016-08-04 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | At the time of inspection, well and site being setup of well plugging activity. Operator anticiaptes to commence plugging early next week. Well tag present and affixed in a permanent manner. No E&S issues in relation to site and/or access road. Department will conduct a follow-up inspection. |
2511469 | Primary Facility | 2016-08-12 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | The service Rig was milling cement down from 3500' to 5617' at the time of this inspection. They plan to cut and retrieve the 5" at this depth. All equipment on site looked ok. |
2511807 | Primary Facility | 2016-08-17 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Inspection performed in response to the receipt of the Notice of Intention to Plug above referenced well. At the time of inspection well plugging ongoing. All equipment and material on secondary containment and appears to be structurally sound. Site stable with no E& S issues in relation to site and/or access road. |
2512156 | Primary Facility | 2016-08-15 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Rig was down to 4400' milling on cement headed for 5617' to retrieve 5" casing at time of inspection. All equipment on site looked ok. |
2512170 | Primary Facility | 2016-08-17 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Rig cut 5" casing @ 5600'-could not pull-cut again @ 5520'-could not pull-cut again @ 5400'-could not pull-ran bond log-tight @ 5350'-shot at 5300'-could not pull-ran free point-cut @ 4000'-slowly pulling pipe. All equipment on site looked ok. |
2514018 | Primary Facility | 2016-08-25 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Rig perfed 4 holes every 100' from 3860' to 3370' to cement-cut and pull casing from 3370'. Running wireline and plan is to cement up to 1391' in 4 500' stages. Equipment looked ok. |
2514036 | Primary Facility | 2016-08-26 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Rig had pulled 5" casing to 3360'- was perfing at time of inspection and plan was to cement to surface later in the day-bail top portion and install vent. Equipment on site looked ok. |
2515925 | Primary Facility | 2016-09-01 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | At the time of inspection well plugging ongoing. Site stable with no E& S issues in relation to site and/or access road. |
2516265 | Primary Facility | 2016-09-01 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Crew had rigged down-moved rig off well bore-cut off vent sub-surface and was preparing to weld elbow on and run vent sub-surface to edge of well pad at time of inspection. All equipment on site looked ok. |
2546584 | Primary Facility | 2016-12-21 | Site Restoration | No Violations Noted | Inspection performed in response to the receipt of the Well Site Restoration Report for the plugging of the above referenced well. At the time of inspection, plugging operations appear to have been completed. Site appears to be restored and stable with no E&S issues in relation to site and/or access road. |
2836708 | Primary Facility | 2019-02-06 | Routine/Complete Inspection | No Violations Noted | 2/6/19 - Well appears to be in good working condition. |