If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-129-28655 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.508006,"lon":-79.545961,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Westmoreland | |
Municipality: Bell Township | |
Operator Name: CNX GAS CO LLC | |
Well Pad ID: 145326 | |
Farm/Lease Name: KUHNS 3A | |
License Status: | |
Spud Date: | |
Permit Date: 2011-08-12 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 40.508006 | |
Longitude: -79.545961 |
Date | Event |
---|---|
2011-08-12 | New Permit Application |
2012-04-13 | Performed Spud Operation |
2012-08-15 | Drilling Completion |
2013-04-25 | Perforation |
2014-03-24 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-06-03 | 2013-06-15 | 7,549 | 6,245,780 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | ||||||||
and (Proppant), DAP-903, DWP-111, DWP-614, DWP-901, BioClear 2000, DWP-NE1, Spearhead Acid, Acetic A |
CWS | Propping Agent, Scale Inhibitor, Gel Slurry, Viscosifier, Breaker, Biocide, Non-Emulsifier, Clean Perforations, Acid, | Crystalline silica (Quartz) | 14808-60-7 | 100 | 11.2778 | 6,652,710.0 | |
Isopropanol | 67-63-0 | 40 | 0.0057 | 3365.69 | ||||
Modified thiourea polymer | 68527-49-1 | 0.1 | 0.0008 | 475.09 | ||||
Propargyl Alcohol | 107-19-7 | 0.1 | 0.0003 | 158.36 | ||||
Methanol | 67-56-1 | 15 | 0.0038 | 2212.31 | ||||
Formaldehyde | 50-00-0 | 0.1 | 0.0001 | 31.67 | ||||
Oxirane, 2-methyl-, polymer with oxirane, monodecyl ether | 37251-67-5 | 1.5 | 0.0003 | 185.78 | ||||
Ammonium Persulfate | 7727-54-0 | 100 | 0.002 | 1167.6 | ||||
Distillates (petroleum), hydrotreated middle | 64742-46-7 | 60 | 0.034 | 20078.2 | ||||
Alkenes, C>10 a- | 64743-02-8 | 0.1 | 0.0008 | 475.09 | ||||
Calcite | 471-34-1 | 1 | 0.0207 | 12222.1 | ||||
Sodium chloride | 7647-14-5 | 0.1 | 0 | 15.84 | ||||
Illite | 12173-60-3 | 1 | 0.0039 | 2307.31 | ||||
Apatite | 64476-38-6 | 0.1 | 0.0024 | 1436.56 | ||||
Polyethylene Glycol Mixture | 25322-68-3 | 70 | 0.0054 | 3183.84 | ||||
Alcohols, C14-15, ethoxylated | 68951-67-7 | 0.1 | 0.0008 | 475.09 | ||||
2,2-Dibromo-3-Nitrilopropionamide | 10222-01-2 | 40 | 0.0054 | 3183.84 | ||||
Fatty acids, tall-oil | 61790-12-3 | 0.1 | 0.0008 | 475.09 | ||||
Hydrochloric acid | 7647-01-0 | 35 | 0.1879 | 110853 | ||||
Diallyldimethylammonium chloride | 7398-69-8 | 5 | 0.0007 | 420.71 | ||||
Poly(oxyethylene)nonylphenol ether | 9016-45-9 | 5 | 0.0036 | 2107.81 | ||||
Ilmenite | 98072-94-7 | 0.1 | 0.0014 | 854.56 | ||||
2-Propenoic acid, polymer with 2-propenamide, sodium salt | 25987-30-8 | 40 | 0.0286 | 16862.5 | ||||
Goethite | 1310-14-1 | 0.1 | 0.0044 | 2600.57 | ||||
Biotite | 1302-27-8 | 0.1 | 0.0024 | 1436.56 | ||||
2-Propenoic acid, polymer with sodium phosphonate | 71050-62-9 | 60 | 0.0067 | 3966.35 | ||||
Quaternary ammonium compounds, bis(hydrogenated tallow alkyl)dimethyl, salts with bentonite |
68953-58-2 | 5 | 0.001 | 619.28 | ||||
Guar gum | 9000-30-0 | 60 | 0.0126 | 7431.37 | ||||
Acetic acid | 64-19-7 | 100 | 0.0248 | 14648.7 | ||||
Dimethylcocoamine, bis(chloroethyl) ether, diquaternary ammonium salt |
68607-28-3 | 40 | 0.0057 | 3365.69 | ||||
Water, | Customer & CWS | Base Fluid & Mix Water, | Water | 7732-18-5 | 100 | 88.3514 | 52,118,100.0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | CNX GAS CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CNX GAS CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | CNX GAS CO LLC | 605,412.74 | 184 | 0.00 | 0 | 0.00 | 0 |
2014 | CNX GAS CO LLC | 635,411.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | CNX GAS CO LLC | 425,493.43 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CNX GAS CO LLC | 298,325.59 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CNX GAS CO LLC | 251,999.45 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CNX GAS CO LLC | 257,106.14 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CNX GAS CO LLC | 206,451.32 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | CNX GAS CO LLC | Drilling Fluid Waste | 870.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CNX GAS CO LLC | Drill Cuttings | 802.21 Tons | LANDFILL | 100434 |
2013 | CNX GAS CO LLC | Produced Fluid | 12,408.45 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CNX GAS CO LLC | Produced Fluid | 351.55 Bbl | INJECTION DISPOSAL WELL | 34-155-23732 |
2013 | CNX GAS CO LLC | Drill Cuttings | 173.15 Tons | LANDFILL | 100434 |
2013 | CNX GAS CO LLC | Produced Fluid | 483.16 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2013 | CNX GAS CO LLC | Produced Fluid | 1,468.15 Bbl | INJECTION DISPOSAL WELL | 34-119-28776 |
2013 | CNX GAS CO LLC | Fracing Fluid Waste | 110.27 Bbl | RESIDUAL WASTE TRANSFER FACILITY | 101674 |
2013 | CNX GAS CO LLC | Produced Fluid | 305.00 Bbl | INJECTION DISPOSAL WELL | 34-167-23862 |
2013 | CNX GAS CO LLC | Produced Fluid | 2,247.11 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2013 | CNX GAS CO LLC | Drill Cuttings | 279.31 Tons | LANDFILL | 301071 |
2013 | CNX GAS CO LLC | Fracing Fluid Waste | 8,715.39 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CNX GAS CO LLC | Produced Fluid | 422.37 Bbl | INJECTION DISPOSAL WELL | 34-155-23759 |
2013 | CNX GAS CO LLC | Drill Cuttings | 149.82 Tons | LANDFILL | 100280 |
2013 | CNX GAS CO LLC | Produced Fluid | 148.59 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2013 | CNX GAS CO LLC | Produced Fluid | 310.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20525 |
2013 | CNX GAS CO LLC | Servicing Fluid | 3.81 Bbl | RESIDUAL WASTE TRANSFER FACILITY | 101674 |
2013 | CNX GAS CO LLC | Produced Fluid | 72.54 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2014 | CNX GAS CO LLC | Produced Fluid | 6,340.44 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CNX GAS CO LLC | Produced Fluid | 768.03 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2014 | CNX GAS CO LLC | Produced Fluid | 214.11 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
2014 | CNX GAS CO LLC | Produced Fluid | 124.57 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2014 | CNX GAS CO LLC | Produced Fluid | 114.66 Bbl | INJECTION DISPOSAL WELL | 34-155-23759 |
2014 | CNX GAS CO LLC | Produced Fluid | 234.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23732 |
2015 | CNX GAS CO LLC | Produced Fluid | 606.99 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2015 | CNX GAS CO LLC | Produced Fluid | 476.19 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2015 | CNX GAS CO LLC | Produced Fluid | 242.00 Bbl | INJECTION DISPOSAL WELL | 34-167-23862 |
2015 | CNX GAS CO LLC | Produced Fluid | 3,963.27 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CNX GAS CO LLC | Produced Fluid | 2,852.28 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CNX GAS CO LLC | Produced Fluid | 200.70 Bbl | INJECTION DISPOSAL WELL | 34-119-28803 |
2016 | CNX GAS CO LLC | Produced Fluid | 120.00 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2017 | CNX GAS CO LLC | Produced Fluid | 301.90 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2017 | CNX GAS CO LLC | Produced Fluid | 110.00 Bbl | REUSE (AT WELL PAD) | |
2017 | CNX GAS CO LLC | Produced Fluid | 690.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-10 |
2017 | CNX GAS CO LLC | Produced Fluid | 117.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2017 | CNX GAS CO LLC | Produced Fluid | 124.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-17 |
2017 | CNX GAS CO LLC | Produced Fluid | 231.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-16 |
2017 | CNX GAS CO LLC | Produced Fluid | 247.00 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2017 | CNX GAS CO LLC | Produced Fluid | 799.33 Bbl | INJECTION DISPOSAL WELL | 34-119-28803 |
2017 | CNX GAS CO LLC | Produced Fluid | 19.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-32 |
2018 | CNX GAS CO LLC | Produced Fluid | 262.85 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2018 | CNX GAS CO LLC | Other Oil & Gas Wastes | 1.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | ODNR 2015-29 |
2018 | CNX GAS CO LLC | Produced Fluid | 250.43 Bbl | INJECTION DISPOSAL WELL | 34-119-28803 |
2018 | CNX GAS CO LLC | Other Oil & Gas Wastes | 22.80 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2018 | CNX GAS CO LLC | Other Oil & Gas Wastes | 24.00 Bbl | REUSE (AT WELL PAD) | |
2018 | CNX GAS CO LLC | Other Oil & Gas Wastes | 2.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2018 | CNX GAS CO LLC | Produced Fluid | 47.26 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-17 |
2018 | CNX GAS CO LLC | Produced Fluid | 1,387.14 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2018 | CNX GAS CO LLC | Produced Fluid | 421.78 Bbl | REUSE (AT WELL PAD) | |
2019 | CNX GAS CO LLC | Produced Fluid | 303.93 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2019 | CNX GAS CO LLC | Produced Fluid | 91.17 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-17 |
2019 | CNX GAS CO LLC | Produced Fluid | 785.21 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2019 | CNX GAS CO LLC | Produced Fluid | 191.11 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | CNX GAS CO LLC | Produced Fluid | 138.26 Bbl | REUSE (AT WELL PAD) | |
2019 | CNX GAS CO LLC | Produced Fluid | 100.18 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2019 | CNX GAS CO LLC | Produced Fluid | 332.40 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2059485 | Primary Facility | 2012-04-16 | Routine/Complete Inspection | No Violations Noted | Inspection in response to a SPUD notice received of Thursday April 12 2012. At the time of inspection the site was being constructed. The E&S plan was on site and was properly implemented. The site was temporary stabilized as outlined in the E&S Plan. The Department notes an unlined pit onsite at the time of inspection. No accelerated erosion observed in relation to the access road or well pad area at the time of the inspection. |
2068974 | Primary Facility | 2012-05-14 | Drilling/Alteration | No Violations Noted | Waiting on rig to commence tophole drilling. |
2086647 | Primary Facility | 2012-07-23 | Drilling/Alteration | No Violations Noted | Waiting on rig to commence tophole drilling. Pit lined and freeboard maintained. Inspection conducted w/OGI Supervisor D. Stivanson. |
2086648 | Primary Facility | 2012-07-26 | Drilling/Alteration | No Violations Noted | Waiting on rig to commence tophole drilling. Pit lined and freeboard maintained. |
2086920 | Primary Facility | 2012-07-23 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the well had not been drilled. The site appeared to be in sound condition. No accelerated or sedimentation observed in relation to the well pad or access road. The site has been temporarily stabilized and all BMP's appear to be properly installed and maintained. THE Department suggest the Operator continue to monitor the site on a weekly basis and after precipitation event to ensure E&S in not leaving the site. |
2089849 | Primary Facility | 2012-08-03 | Routine/Complete Inspection | No Violations Noted | Due to lost cement circulation and inadvertent returns in last well on 20” casing, the following work was done to prep the hole for this particular location: |
2092776 | Primary Facility | 2012-08-06 | Drilling/Alteration | No Violations Noted | 20” casing ran and cemented during inspection. No inadvertent returns for the duration of the cement job inspection. Closed loop system being utilized. Pit lined and freeboard maintained. |
2092856 | Primary Facility | 2012-08-20 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the well was drilled but not equipped for production. The well pad appeared to be in sound condition. No accelerated erosion or sedimentation observed. The pit located onsite appeared to in sound condition and had the required 2 feet of free board. The Department suggests the operator continue to monitor the site weekly and after precipitation events to ensure the stability of the site is retained. |
2097838 | Primary Facility | 2012-09-05 | Drilling/Alteration | No Violations Noted | Waiting on rig to commence lateral drilling. Pit lined and freeboard maintained. |
2127552 | Primary Facility | 2013-01-03 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the well was drilled but not equipped for production. The well pad appeared to be in sound condition. No accelerated erosion or sedimentation observed. The pit located onsite appeared to in sound condition and had the required 2 feet of free board. The Department suggests the operator continue to monitor the site weekly and after precipitation events to ensure the stability of the site is retained. |
2134655 | Primary Facility | 2013-01-25 | Drilling/Alteration | No Violations Noted | Waiting on rig to commence lateral drilling. Pit lined and freeboard maintained. Inspection conducted w/OGI D. Catalano. |
2138179 | Primary Facility | 2013-02-11 | Routine/Complete Inspection | No Violations Noted | no violations noted |
2145944 | Primary Facility | 2013-02-28 | Drilling/Alteration | No Violations Noted | Waiting on frac. Pit lined and freeboard maintained. |
2147740 | Primary Facility | 2013-03-12 | Routine/Complete Inspection | No Violations Noted | no violations |
2147818 | Primary Facility | 2013-03-12 | Drilling/Alteration | No Violations Noted | Waiting on frac. Pit lined and freeboard maintained. |
2151216 | Primary Facility | 2013-03-26 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the Operator indicated the well was drilled to total depth. The well pad appeared to be in sound condition with secondary containment underneath the drill rig. No accelerated erosion or sedimentation observed. The pit located onsite appeared to in sound condition and had the required 2 feet of free board. The Department suggests the operator continue to monitor the site weekly and after precipitation events to ensure the stability of the site is retained. |
2160373 | Primary Facility | 2013-04-22 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the well was drilled however not stimulated or equipped for production. During the inspection the Department notes that the Operator has started to prepare the site for stimulation. The Operator was in the process of excavating an area adjacent to the pad to store the Rock Water above ground storage container. The erosions and sedimentation plan was onsite and all associated BMPs appear to installed and functioning as outline in the plan. No accelerated erosion or sedimentation observed. The pit located onsite appeared to in sound condition and had the required 2 feet of free board. The Department suggests the operator continue to monitor the site weekly and after precipitation events to ensure the stability of the site is retained. |
2166674 | Primary Facility | 2013-05-15 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the well was drilled and the Operator was in the final stages of the stimulation set up process. Stimulation notice received by the Department on 5/11/2013 set for 5/16/2013. The Department notes that a 1 million gallon above ground freshwater containment vessel was installed and being filled at the time of inspection. The Department suggests the operator continue to monitor the site weekly and after precipitation events to ensure the stability of the site is retained. |
2171429 | Primary Facility | 2013-06-03 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the well was drilled and the Operator was in the process of stimulation. No observation of accelerated erosion or sedimentation in relation the well pad or access road. The E&S plan was onsite and all associated BMPs appear to be installed and properly maintained. The Department suggests the operator continue to monitor the site weekly and after precipitation events to ensure the stability of the site is retained.Refer to inspection # 2171660 for violations issued on 6/3/2013 for release during completions operations. |
2185900 | Primary Facility | 2013-07-24 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the well was drilled and stimulated and the Operator was in the process of equipping the well for production. The Department notes that the Operator has installed the previously approved Rock Water flow back tank. The Department notes that the flow back tank appears to be in sound condition and is placed within containment. No observation of accelerated erosion or sedimentation in relation the well pad or access road. The E&S plan was onsite and all associated BMPs appear to be installed and properly maintained. The Department suggests the operator continue to monitor the site weekly and after precipitation events to ensure the stability of the site is retained. |
2199828 | Primary Facility | 2013-08-29 | Incident- Response to Accident or Event | No Violations Noted | Inspection the result of the Operator reporting a pit overrun and possible BMP failures due to an extreme rain fall event on 8.28.2013. During the inspection the Operator indicated and the Department recognized that the pit that over ran was a lined emergency pit located adjacent to the Kuhns Well pad. The pit was never used to hold any pollutional substances at any point prior to the extreme precipitation event. Also during the inspection the Department inspected the BMPs associated with the adjacent pipeline and well site. The BMPs installed by the Operator appeared to function properly, this fact coupled with the vegetative coverage achieved on the fill side of the well site and the pipeline right of way appeared to limit accelerated erosion and sedimentation. The Department suggest the Operator submit metrological data supporting the extreme rainfall claimed and weekly site inspection report from 7.28.2013 until the event on 8.28.2013. |
2240335 | Primary Facility | 2013-01-28 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the well appear to be drilled and in production. Update to inspection #2199828, the pending violations from 8/29/2013 have been removed.. See attachments for rainfall data and sample results. |
2281844 | Primary Facility | 2014-06-24 | Routine/Complete Inspection | No Violations Noted | Well operating and properly identified. |
2358471 | Primary Facility | 2015-04-07 | Routine/Complete Inspection | No Violations Noted | Well operating and properly identified. |
2476209 | Primary Facility | 2016-04-19 | Routine/Complete Inspection | No Violations Noted | Well tagged-in production. Well head casing-production unit equipment-tank battery-dike look ok. |
2521548 | Primary Facility | 2016-09-21 | Routine/Complete Inspection | No Violations Noted | At the time of inspection well appears equipped for production. Well tag present and affixed in a permanent manner. Brine tank located on site within secondary containment and appears to be structurally sound. Site stable, no E& S issues in relation to site and/or access road. |
2576104 | Primary Facility | 2017-03-27 | Routine/Complete Inspection | No Violations Noted | Well tagged-in production. Well head casing-production set equipment-tank battery-dike containment looked ok. |
2622362 | Primary Facility | 2017-08-04 | Routine/Complete Inspection | No Violations Noted | At the time of inspection well equipped for production. Brine tank within secondary containment and appears to be structurally sound. No E&S issues. |
2738493 | Primary Facility | 2018-06-07 | Routine/Complete Inspection | No Violations Noted | 6-7-18 Well producing. |
2843845 | Primary Facility | 2019-02-25 | Routine/Complete Inspection | No Violations Noted | This well is tagged and in production. The well head casing, piping, production set equipment, containment dike and tank battery look ok. |
For data sources see[8]