{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.508125,"lon":-79.545814,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Westmoreland | |
Municipality: Bell Township | |
Operator Name: CNX GAS CO LLC | |
Well Pad ID: 145326 | |
Farm/Lease Name: KUHNS 3D | |
License Status: | |
Spud Date: | |
Permit Date: 2012-04-12 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 40.508125 | |
Longitude: -79.545814 |
Date | Event |
---|---|
2012-04-12 | New Permit Application |
2012-04-12 | Performed Spud Operation |
2012-07-12 | Drilling Completion |
2013-05-01 | Perforation |
2014-03-26 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-05-20 | 2013-06-01 | 7,484 | 9,452,650 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | ||||||||
and (Proppant), DAP-903, DWP-111, DWP-614, DWP-690, DWP-901, BioClear 2000, DWP-NE1, Spearhead Acid, |
CWS | Propping Agent, Scale Inhibitor, Gel Slurry, Viscosifier, Breaker, Breaker, Biocide, Non-Emulsifier, Clean Perforations, Acid, | Inorganic base | Proprietary | 0 | 0 | 0 | |
Cupric chloride | 7447-39-4 | 0 | 0 | 0 | ||||
Sulfonated hydrocarbon | Proprietary | 0 | 0 | 0 | ||||
Sodium bromide | 7647-15-6 | 0 | 0 | 0 | ||||
Alkaryl compound | Proprietary | 0 | 0 | 0 | ||||
Oxoalkyl compounds (2) | Proprietary | 0 | 0 | 0 | ||||
Dimethylcocoamine, bis(chloroethyl) ether, diquaternary ammonium salt |
68607-28-3 | 40 | 0.0247 | 19569.6 | ||||
Erythorbic acid | 89-65-6 | 0 | 0 | 0 | ||||
Direct red 81 | 2610-11-9 | 0.1 | 0 | 7.45 | ||||
Mullite | 1302-93-8 | 0 | 0 | 0 | ||||
Inorganic acid | Proprietary | 0 | 0 | 0 | ||||
Silicon dioxide | 7631-86-9 | 0 | 0 | 0 | ||||
Ammonium sulphate | 7783-20-2 | 0 | 0 | 0 | ||||
Polyoxyalkylenes | Proprietary | 0 | 0 | 0 | ||||
Monoethanolamine | 141-43-5 | 0 | 0 | 0 | ||||
Alkyl phenyl ethoxylate | 68412-54-4 | 0 | 0 | 0 | ||||
2-Propenoic acid, polymer with 2-propenamide, sodium salt | 25987-30-8 | 40 | 0.0472 | 37311.8 | ||||
Illite | 12173-60-3 | 1 | 0.0038 | 2976.21 | ||||
Oxyalkylated polyamine | Proprietary | 0 | 0 | 0 | ||||
Quaternary ammonium compounds, bis(hydrogenated tallow alkyl)dimethyl, salts with bentonite |
68953-58-2 | 5 | 0.0021 | 1633.69 | ||||
Borate salt | Proprietary | 0 | 0 | 0 | ||||
2,2-Dibromo-3-Nitrilopropionamide | 10222-01-2 | 40 | 0.0072 | 5716.78 | ||||
Formaldehyde | 50-00-0 | 0.1 | 0.0001 | 41.67 | ||||
Distillates (petroleum), hydrotreated middle | 64742-46-7 | 60 | 0.0602 | 47588.1 | ||||
Formic Acid | 64-18-6 | 0 | 0 | 0 | ||||
Polyacrylamide polymer | Proprietary | 0 | 0 | 0 | ||||
Styrene acrylic copolymer | 25085-34-1 | 0 | 0 | 0 | ||||
Poly(oxyethylene)nonylphenol ether | 9016-45-9 | 5 | 0.0059 | 4663.98 | ||||
Calcium oxide (CaO) | 1305-78-8 | 0 | 0 | 0 | ||||
Guar gum | 9000-30-0 | 60 | 0.0248 | 19604.3 | ||||
Hydroxylated hydrocarbon | Proprietary | 0 | 0 | 0 | ||||
Magnesium chloride | 7786-30-3 | 0 | 0 | 0 | ||||
2-Propenoic acid, polymer with sodium phosphonate | 71050-62-9 | 60 | 0.0076 | 6024.89 | ||||
Benzene, (1-methylethyl)- | 98-82-8 | 0 | 0 | 0 | ||||
Hydrated clay | Proprietary | 0 | 0 | 0 | ||||
Acetic acid | 64-19-7 | 100 | 0.0272 | 21542.2 | ||||
Water, | Customer & CWS | Base Fluid & Mix Water, | Water | 7732-18-5 | 100 | 99.7892 | 78,912,100.0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | CNX GAS CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | CNX GAS CO LLC | 966,091.46 | 184 | 0.00 | 0 | 0.00 | 0 |
2014 | CNX GAS CO LLC | 1,315,486.82 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | CNX GAS CO LLC | 878,087.68 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CNX GAS CO LLC | 676,788.33 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CNX GAS CO LLC | 560,022.06 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CNX GAS CO LLC | 495,059.04 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CNX GAS CO LLC | 430,554.85 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | CNX GAS CO LLC | Drill Cuttings | 706.50 Tons | LANDFILL | 100434 |
2013 | CNX GAS CO LLC | Produced Fluid | 7,363.28 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CNX GAS CO LLC | Produced Fluid | 271.05 Bbl | INJECTION DISPOSAL WELL | 34-155-23732 |
2013 | CNX GAS CO LLC | Produced Fluid | 33.33 Bbl | INJECTION DISPOSAL WELL | 34-155-23203 |
2013 | CNX GAS CO LLC | Drilling Fluid Waste | 95.97 Bbl | LANDFILL | 301071 |
2013 | CNX GAS CO LLC | Drilling Fluid Waste | 94.19 Bbl | LANDFILL | 100280 |
2013 | CNX GAS CO LLC | Produced Fluid | 115.83 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
2013 | CNX GAS CO LLC | Drilling Fluid Waste | 10.12 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2013 | CNX GAS CO LLC | Produced Fluid | 453.96 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2013 | CNX GAS CO LLC | Produced Fluid | 1,266.36 Bbl | INJECTION DISPOSAL WELL | 34-119-28776 |
2013 | CNX GAS CO LLC | Fracing Fluid Waste | 110.28 Bbl | RESIDUAL WASTE TRANSFER FACILITY | 101674 |
2013 | CNX GAS CO LLC | Produced Fluid | 33.34 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2013 | CNX GAS CO LLC | Produced Fluid | 205.00 Bbl | INJECTION DISPOSAL WELL | 34-167-23862 |
2013 | CNX GAS CO LLC | Produced Fluid | 375.79 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2013 | CNX GAS CO LLC | Drill Cuttings | 437.41 Tons | LANDFILL | 301071 |
2013 | CNX GAS CO LLC | Fracing Fluid Waste | 9,180.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CNX GAS CO LLC | Produced Fluid | 210.08 Bbl | INJECTION DISPOSAL WELL | 34-155-23759 |
2013 | CNX GAS CO LLC | Produced Fluid | 104.13 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2013 | CNX GAS CO LLC | Produced Fluid | 33.33 Bbl | INJECTION DISPOSAL WELL | 34-155-21894 |
2013 | CNX GAS CO LLC | Produced Fluid | 100.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20525 |
2013 | CNX GAS CO LLC | Produced Fluid | 250.38 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2014 | CNX GAS CO LLC | Produced Fluid | 5,660.43 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CNX GAS CO LLC | Produced Fluid | 1,145.43 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2014 | CNX GAS CO LLC | Produced Fluid | 32.76 Bbl | INJECTION DISPOSAL WELL | 34-119-28776 |
2014 | CNX GAS CO LLC | Produced Fluid | 241.02 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
2014 | CNX GAS CO LLC | Produced Fluid | 252.72 Bbl | INJECTION DISPOSAL WELL | 34-155-23759 |
2014 | CNX GAS CO LLC | Produced Fluid | 105.87 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2015 | CNX GAS CO LLC | Produced Fluid | 430.85 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2015 | CNX GAS CO LLC | Produced Fluid | 349.57 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2015 | CNX GAS CO LLC | Produced Fluid | 3,132.07 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CNX GAS CO LLC | Produced Fluid | 2,038.90 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CNX GAS CO LLC | Produced Fluid | 122.85 Bbl | INJECTION DISPOSAL WELL | 34-119-28803 |
2016 | CNX GAS CO LLC | Produced Fluid | 187.65 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2017 | CNX GAS CO LLC | Produced Fluid | 328.00 Bbl | REUSE (AT WELL PAD) | |
2017 | CNX GAS CO LLC | Produced Fluid | 456.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-10 |
2017 | CNX GAS CO LLC | Produced Fluid | 108.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2017 | CNX GAS CO LLC | Produced Fluid | 117.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-16 |
2017 | CNX GAS CO LLC | Produced Fluid | 112.00 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2017 | CNX GAS CO LLC | Produced Fluid | 552.16 Bbl | INJECTION DISPOSAL WELL | 34-119-28803 |
2017 | CNX GAS CO LLC | Produced Fluid | 138.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-32 |
2018 | CNX GAS CO LLC | Produced Fluid | 262.85 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2018 | CNX GAS CO LLC | Other Oil & Gas Wastes | 1.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | ODNR 2015-29 |
2018 | CNX GAS CO LLC | Produced Fluid | 257.44 Bbl | INJECTION DISPOSAL WELL | 34-119-28803 |
2018 | CNX GAS CO LLC | Other Oil & Gas Wastes | 22.80 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2018 | CNX GAS CO LLC | Other Oil & Gas Wastes | 2.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2018 | CNX GAS CO LLC | Other Oil & Gas Wastes | 24.00 Bbl | REUSE (AT WELL PAD) | |
2018 | CNX GAS CO LLC | Produced Fluid | 47.26 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-17 |
2018 | CNX GAS CO LLC | Produced Fluid | 1,387.14 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2018 | CNX GAS CO LLC | Produced Fluid | 421.78 Bbl | REUSE (AT WELL PAD) | |
2019 | CNX GAS CO LLC | Produced Fluid | 303.93 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2019 | CNX GAS CO LLC | Produced Fluid | 91.17 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-17 |
2019 | CNX GAS CO LLC | Produced Fluid | 100.18 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2019 | CNX GAS CO LLC | Produced Fluid | 785.21 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2019 | CNX GAS CO LLC | Produced Fluid | 191.11 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | CNX GAS CO LLC | Produced Fluid | 138.26 Bbl | REUSE (AT WELL PAD) | |
2019 | CNX GAS CO LLC | Produced Fluid | 332.40 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2068986 | Primary Facility | 2012-05-14 | Drilling/Alteration | No Violations Noted | Waiting on rig to commence tophole drilling. |
2080108 | Primary Facility | 2012-06-21 | Drilling/Alteration | No Violations Noted | Falcon Drilling rig#28 drilling at 527'. Cleaning out plugged flowline at time of inspection. Closed loop system being utilized. |
2086674 | Primary Facility | 2012-07-23 | Drilling/Alteration | No Violations Noted | Waiting on rig to commence lateral drilling. Pit lined and freeboard maintained. Inspection conducted w/OGI Supervisor D. Stivanson. |
2086675 | Primary Facility | 2012-07-26 | Drilling/Alteration | No Violations Noted | Waiting on rig to commence lateral drilling. Pit lined and freeboard maintained. |
2092781 | Primary Facility | 2012-08-06 | Drilling/Alteration | No Violations Noted | Waiting on rig to commence lateral drilling. Pit lined and freeboard maintained. |
2097895 | Primary Facility | 2012-09-05 | Drilling/Alteration | No Violations Noted | Waiting on rig to commence lateral drilling. Pit lined and freeboard maintained. |
2134664 | Primary Facility | 2013-01-25 | Drilling/Alteration | No Violations Noted | Waiting on rig to commence lateral drilling. Pit lined and freeboard maintained. Inspection conducted w/OGI D. Catalano. |
2145987 | Primary Facility | 2013-02-28 | Drilling/Alteration | No Violations Noted | Patterson rig#331 kicking off to build curve (6381’) at time of inspection (12.1 lb/gal synthetic-based oil mud). Pit lined and freeboard maintained. |
2147827 | Primary Facility | 2013-03-12 | Drilling/Alteration | No Violations Noted | Waiting on frac. Pit lined and freeboard maintained. |
2184316 | Primary Facility | 2012-04-16 | Routine/Complete Inspection | No Violations Noted | Inspection in response to a SPUD notice received of Thursday April 12 2012. At the time of inspection the site was being constructed. The E&S plan was on site and was properly implemented. The site was temporary stabilized as outlined in the E&S Plan. The Department notes an unlined pit onsite at the time of inspection. No accelerated erosion observed in relation to the access road or well pad area at the time of the inspection. Update to inspection ID# 2059495. |
2184317 | Primary Facility | 2012-07-23 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the well was drilled to the kickoff depth. The site appeared to be in sound condition. No accelerated or sedimentation observed in relation to the well pad or access road. The site has been temporarily stabilized and all BMP's appear to be properly installed and maintained. THE Department suggest the Operator continue to monitor the site on a weekly basis and after precipitation event to ensure E&S in not leaving the site. Update to inspection ID # 2086918. |
2184320 | Primary Facility | 2012-08-20 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the well was drilled but not equipped for production. The well pad appeared to be in sound condition. No accelerated erosion or sedimentation observed. The pit located onsite appeared to in sound condition and had the required 2 feet of free board. The Department suggests the operator continue to monitor the site weekly and after precipitation events to ensure the stability of the site is retained. Update to inspection ID # 2092854. |
2184322 | Primary Facility | 2013-01-03 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the well was drilled but not equipped for production. The well pad appeared to be in sound condition. No accelerated erosion or sedimentation observed. The pit located onsite appeared to in sound condition and had the required 2 feet of free board. The Department suggests the operator continue to monitor the site weekly and after precipitation events to ensure the stability of the site is retained. Update to inspection ID # 2127551. |
2184324 | Primary Facility | 2013-02-11 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the Drill Rig was on site and preparing to drill the lateral portion of the well. The well pad appeared to be in sound condition with secondary containment underneath the drill rig. No accelerated erosion or sedimentation observed. The pit located onsite appeared to in sound condition and had the required 2 feet of free board. The Department suggests the operator continue to monitor the site weekly and after precipitation events to ensure the stability of the site is retained. Update to inspection ID # 2138177. |
2184325 | Primary Facility | 2013-03-14 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the Operator indicated the well was drilled to total depth. The well pad appeared to be in sound condition with secondary containment underneath the drill rig. No accelerated erosion or sedimentation observed. The pit located onsite appeared to in sound condition and had the required 2 feet of free board. The Department suggests the operator continue to monitor the site weekly and after precipitation events to ensure the stability of the site is retained. Update to inspection ID # 2147679. |
2184327 | Primary Facility | 2013-03-26 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the Operator indicated the well was drilled to total depth. The well pad appeared to be in sound condition with secondary containment underneath the drill rig. No accelerated erosion or sedimentation observed. The pit located onsite appeared to in sound condition and had the required 2 feet of free board. The Department suggests the operator continue to monitor the site weekly and after precipitation events to ensure the stability of the site is retained. Update to inspection ID # 2151214. |
2184330 | Primary Facility | 2013-04-22 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the well was drilled however not stimulated or equipped for production. During the inspection the Department notes that the Operator has started to prepare the site for stimulation. The Operator was in the process of excavating an area adjacent to the pad to store the Rock Water above ground storage container. The erosions and sedimentation plan was onsite and all associated BMPs appear to installed and functioning as outline in the plan. No accelerated erosion or sedimentation observed. The pit located onsite appeared to in sound condition and had the required 2 feet of free board. The Department suggests the operator continue to monitor the site weekly and after precipitation events to ensure the stability of the site is retained. Update to inspection ID # 2160371. |
2184334 | Primary Facility | 2013-05-15 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the well was drilled and the Operator was in the final stages of the stimulation set up process. Stimulation notice received by the Department on 5/11/2013 set for 5/16/2013. The Department notes that a 1 million gallon above ground freshwater containment vessel was installed and being filled at the time of inspection. The Department suggests the operator continue to monitor the site weekly and after precipitation events to ensure the stability of the site is retained. Update to inspection ID #2166673. |
2184351 | Primary Facility | 2013-06-03 | Incident- Response to Accident or Event | Violation(s) Noted | violations notes and Update to inspection ID #2171660, which has been deleted. The inspection was recorded against the incorrect permit number, which was voided and redesignated. |
2185918 | Primary Facility | 2013-07-24 | Compliance Evaluation | No Violations Noted | CEI inspection to violations written on 6/3/2013. At the time of inspection the affected area has been remediated and backfilled. The Operators response’s from 06/15/2013 and 06/28/2013 have been reviewed by and approved by the Department. The E&S plan was on site and appears to implemented as designed. All BMPs appear to be installed and functioning properly. The Department also suggests the Operator continue to monitor the site weekly and after significant precipitation event to ensure the site stability is maintained. |
2199863 | Primary Facility | 2013-08-29 | Routine/Complete Inspection | No Violations Noted | See inspection #2199829 for observations of made during the 8.29.2013 inspection well pad. |
2240342 | Primary Facility | 2014-01-28 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the well appear to be drilled and in production. The well apparatus and brine tanks appear to be in sound condition. The site is covered with snow no E&S inspection could be conducted during the inspection. |
2281842 | Primary Facility | 2014-06-24 | Routine/Complete Inspection | No Violations Noted | Well operating and properly identified. |
2358476 | Primary Facility | 2015-04-07 | Routine/Complete Inspection | No Violations Noted | Well operating and properly identified. |
2476201 | Primary Facility | 2016-04-19 | Routine/Complete Inspection | No Violations Noted | Well tagged-in production. Well head casing-production unit equipment-tank battery-dike look ok. |
2521538 | Primary Facility | 2016-09-21 | Routine/Complete Inspection | No Violations Noted | At the time of inspection well appears equipped for production. Well tag present and affixed in a permanent manner. Brine tank located on site within secondary containment and appears to be structurally sound. Site stable, no E& S issues in relation to site and/or access road. |
2576098 | Primary Facility | 2017-03-27 | Routine/Complete Inspection | No Violations Noted | Well tagged-in producton. Well head casing-production set equipment-tank battery-dike contaniment looked ok. |
2622370 | Primary Facility | 2017-08-04 | Routine/Complete Inspection | No Violations Noted | At the time of inspection well equipped for production. Brine tank within secondary containment and appears to be structurally sound. No E&S issues. |
2738502 | Primary Facility | 2018-06-07 | Routine/Complete Inspection | No Violations Noted | 6-7-18 Well producing. |
2843833 | Primary Facility | 2019-02-25 | Routine/Complete Inspection | No Violations Noted | This well is tagged and in production. The well head casing, piping, production set equipment, containment dike and tank battery look ok. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2184351 | 672878 | 06/03/2013 | 2013-06-03 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | update to violation ID 66916 |
2184351 | 672879 | 06/03/2013 | 2013-06-03 | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | Environmental Health & Safety | upate to violation ID 669515 |
2184351 | 672880 | 06/03/2013 | 2013-06-03 | 301CSL - Stream discharge of IW, includes drill cuttings, oil, brine and/or silt | Environmental Health & Safety | undate to violation id 672875 |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
672878 | 299879 | NOV - Notice of Violation | Comply/Closed | 2013-07-24 | |||
672879 | 299879 | NOV - Notice of Violation | Comply/Closed | 2013-07-24 | |||
672880 | 299879 | NOV - Notice of Violation | Comply/Closed | 2013-07-24 |