{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.600667,"lon":-76.014763,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Wyoming | |
Municipality: Meshoppen Township | |
Operator Name: BKV OPR LLC | |
Well Pad ID: 148995 | |
Farm/Lease Name: P&G WAREHOUSE UNIT 1 1H | |
License Status: | |
Spud Date: 2011-06-09 | |
Permit Date: 2010-08-19 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.600667 | |
Longitude: -76.014763 |
Date | Event |
---|---|
2010-08-19 | New Permit Application |
2011-06-08 | Performed Spud Operation |
2011-09-22 | Drilling Completion |
2011-11-29 | Perforation |
2011-11-29 | Performed Stimulation |
2013-01-16 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2011-11-29 | 2011-11-29 | 7,991 | 7,891,128 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | SI-100 | Universal Well Services | Scale Inhibitor | |||||
Ethylene glycol | 107-21-1 | 60.00 | 0.02 | |||||
7.5-15 HCL | Universal Well Services | Acid | Water | 7732-18-5 | 92.50 | |||
Hydrochloric acid | 7647-01-0 | 15.00 | 0.07 | |||||
Unislik ST 50 | Universal Well Services | Friction Reducer | Hydrotreated Light Distillate | 30.00 | 0.06 | |||
Biocide EC 6116A | Universal Well Services | Biocide | ||||||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30.00 | ||||||
Polyethylene glycol | 25322-68-3 | 60.00 | ||||||
Dibromoacetonitrile | 3252-43-5 | 5.00 | 0.04 | |||||
SuperSurf | Universal Well Services | Surfactant | ||||||
Methanol | 67-56-1 | 60.00 | 0.07 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2011-11-29 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | CITRUS ENERGY CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | CITRUS ENERGY CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CITRUS ENERGY CORP | 3,623,747.00 | 330 | 0.00 | 0 | 0.00 | 0 |
2013 | CITRUS ENERGY CORP | 1,822,351.00 | 319 | 0.00 | 0 | 0.00 | 0 |
2014 | WARREN E & P INC | 1,332,854.75 | 346 | 0.00 | 0 | 0.00 | 0 |
2015 | WARREN E & P INC | 974,720.69 | 359 | 0.00 | 0 | 0.00 | 0 |
2016 | WARREN E & P INC | 682,328.77 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | WARREN E & P INC | 794,099.59 | 364 | 0.00 | 0 | 0.00 | 0 |
2018 | BKV OPR LLC | 839,187.31 | 361 | 0.00 | 0 | 0.00 | 0 |
2019 | BKV OPR LLC | 214,530.13 | 231 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | CITRUS ENERGY CORP | Drill Cuttings | 774.00 Tons | LANDFILL | 101247 |
2011 | CITRUS ENERGY CORP | Drill Cuttings | 1,250.00 Tons | LANDFILL | THR029 |
2013 | CITRUS ENERGY CORP | Produced Fluid | 718.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | WARREN E & P INC | Produced Fluid | 100.00 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2014 | CITRUS ENERGY CORP | Produced Fluid | 240.77 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | WARREN E & P INC | Produced Fluid | 285.28 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | WARREN E & P INC | Produced Fluid | 190.80 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2016 | WARREN E & P INC | Other Oil & Gas Wastes | 57.34 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2016 | WARREN E & P INC | Other Oil & Gas Wastes | 27.87 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2016 | WARREN E & P INC | Other Oil & Gas Wastes | 39.33 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2016 | WARREN E & P INC | Produced Fluid | 215.09 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2016 | WARREN E & P INC | Produced Fluid | 44.51 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2016 | WARREN E & P INC | Produced Fluid | 139.28 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2016 | WARREN E & P INC | Other Oil & Gas Wastes | 5.38 Tons | LANDFILL | THR029 |
2017 | WARREN E & P INC | Other Oil & Gas Wastes | 1.33 Bbl | REUSE (AT WELL PAD) | |
2017 | WARREN E & P INC | Other Oil & Gas Wastes | 73.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | WARREN E & P INC | Produced Fluid | 559.70 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | WARREN E & P INC | Produced Fluid | 42.85 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2017 | WARREN E & P INC | Produced Fluid | 112.16 Bbl | REUSE (AT WELL PAD) | |
2018 | WARREN E & P INC | Produced Fluid | 262.33 Bbl | REUSE (AT WELL PAD) | |
2018 | WARREN E & P INC | Other Oil & Gas Wastes | 92.30 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018 | WARREN E & P INC | Produced Fluid | 830.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018 | BKV OPR LLC | Produced Fluid | 74.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2019 | BKV OPR LLC | Waste Water Treatment Sludge | 9.76 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101714 |
2019 | BKV OPR LLC | Soil Contaminated by Oil & Gas Related Spills | 6.02 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101714 |
2019 | BKV OPR LLC | Soil Contaminated by Oil | 6.02 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101714 |
2019 | BKV OPR LLC | Produced Fluid | 18.33 Bbl | REUSE (AT WELL PAD) | |
2019 | BKV OPR LLC | Produced Fluid | 144.17 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2019 | BKV OPR LLC | Waste Water Treatment Sludge | 0.47 Tons | RESIDUAL WASTE PROCESSING FACILITY | 301280 |
2019 | BKV OPR LLC | Produced Fluid | 1,992.34 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1995772 | Primary Facility | 2011-08-09 | Routine/Complete Inspection | Violation(s) Noted | |
1999491 | Primary Facility | 2011-08-30 | Drilling/Alteration | No Violations Noted | Patterson UTI Rig 61, Comp Man - Dale Barnett - not here(talked to Jacob Oettel - Patterson) |
2000511 | Primary Facility | 2011-09-02 | Drilling/Alteration | No Violations Noted | 260' off bottom got stuck, worked pipe for about 2 hr, no luck getting free, getting surf jars, won't be cementing til ? later. |
2002507 | Primary Facility | 2011-09-01 | Drilling/Alteration | No Violations Noted | Checked drillers log, at 955'. |
2002532 | Primary Facility | 2011-09-06 | Drilling/Alteration | No Violations Noted | Patterson UTI Rig 61, Comp. Man - Joey Catlin, Checked drillers log, @ 4154' |
2002538 | Primary Facility | 2011-09-13 | Drilling/Alteration | No Violations Noted | Patterson UTI Rig 61, Comp. Man - Joey Catlin, Checked drillers log, at 8367' |
2004596 | Primary Facility | 2011-09-20 | Drilling/Alteration | No Violations Noted | Patterson UTI Rig 61 Comp. Man - Joey Catlin |
2012963 | Primary Facility | 2011-10-11 | Routine/Complete Inspection | No Violations Noted | Inspected conditions of pit before it is closed. Liner has been removed. Water is seeping in from oversaturated water table. No evidence of contamination. Will conduct follow-up when the pit is filled in. |
2012964 | Primary Facility | 2011-10-17 | Follow-up Inspection | No Violations Noted | Pit has been filled in. Surface has been seeded and mulched. No evidence of seeps opening or contamination. |
2368507 | Primary Facility | 2015-05-11 | Routine/Partial Inspection | No Violations Noted | |
2429743 | Primary Facility | 2015-12-03 | Routine/Complete Inspection | No Violations Noted | |
2671109 | Primary Facility | 2017-12-13 | Routine/Complete Inspection | No Violations Noted | Arrived onsite at 14:00. Weather: Clear, Cold, ~ 25 degs. (3) active wells on this location, the P&G Warehouse 1H, Lasco 2H and McCarthy 3H. All (3) wells were producing at time of inspection. All wells prod. pressures are being monitored by wireless sending units, "SCADA" gauges. Sending data to Total Flow Control units "TFCU". All wells had (2) annular vents present. The (9x5) vents were tied into vent piping running to prod. tanks. The (13x9) vents were venting to atmosphere. Gas checks were performed at the (13x9) vent openings, using a Altair 5X gas meter. Gas checks showed ~ 75% LEL, 2% CH4, no measurable flow noted at time of imsp. While on location, Warrens' Field Rep., Scott Moyel arrived onsite. Mr. Moyel informed that the quarterly Mechanical Integrity Assessment "MIA", shut-in tests, had just been completed on these wells annuli. That is why the wells (13x9) vents were venting to atmosphere and that these annuli will be tied back into the common vent line to prod. tanks. This could also account f |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1995772 | 617783 | 08/09/2011 | 2011-08-09 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | Compost filter sock is partially submerged due to water discharging from near tanks. Discharging water has caused channelling in berm. Filter sock installed with rebar, it is unclear if installation was approved by Department. |
1995772 | 617784 | 08/09/2011 | 2011-08-09 | 102.4INADPLN - E&S Plan not adequate | Administrative | No record or weekly/post-storm inspection reports being conducted. |