37-131-20092

Well Details

Well ID: 37-131-20092
Loading map...
Country: United States
State: Pennsylvania
County: Wyoming
Municipality: Monroe Township
Operator Name: CARRIZO (MARCELLUS) LLC
Well Pad ID: 145341
Farm/Lease Name: SHIELDS 1V
License Status:
Spud Date: 2011-01-21
Permit Date: 2010-09-14
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: No
Latitude: 41.421225
Longitude: -76.039050

For data sources see[1][2][3]

Well History

Date Event
2010-09-14 New Permit Application
2011-01-06 Performed Spud Operation
2011-02-06 Drilling Completion
2011-07-27 Fully Plugged

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CARRIZO (MARCELLUS) LLC 0.00 0 0.00 0 0.00 0
2011 CARRIZO (MARCELLUS) LLC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CARRIZO (MARCELLUS) LLC Drilling Fluid Waste 454.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2011 CARRIZO (MARCELLUS) LLC Drilling Fluid Waste 2,679.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2011 CARRIZO (MARCELLUS) LLC Drill Cuttings 597.00 Tons LANDFILL NY31346244

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1941183 Primary Facility 2011-01-06 Routine/Complete Inspection No Violations Noted
1944789 Primary Facility 2011-01-24 Complaint Inspection No Violations Noted
1946683 Primary Facility 2011-01-24 Drilling/Alteration No Violations Noted UDI- Rig 46. Company Man Scott Schultz. Crew assembling 11 3/4 casing and running in hole upon arrival. DEP stayed on site to observe cement job. At @ 23:30, BJ Services begin pumping cement. 15.4 wt/ Y - 1.23/ 0.5% gasblok. 540 sks gastite cement. Had 55 bbls returns. Casing set at 716'. Final weight of cement on flow line was checked with mud scale= 14.5. Plug landed at 01:45, float held. WOC 8 hrs.
1946716 Primary Facility 2011-01-26 Follow-up Inspection Viol(s) Noted & Immediately Corrected Scott Schultz- Co. Man. FUI on spill of drill cuttings/mud. Solids handling contractor penetrated bottom of open-top mud tub with excavator teeth while mixing solids. Lost a reported 50 bbls of drill cuttings/mud onto plastic under tub. Spilled material was immediately cleaned up and disposed of. Tub was emptied and hole in bottom of tub was patched. Spill occurred @05:00 on 1/25/11. Reported by Gary Byron from carizzo.
1946992 Primary Facility 2011-02-02 Complaint Inspection No Violations Noted I received analysis results for the methane sampling suite. The results indicated a detection for methane (0.0163 mg/L). I compared this with pre-drill test results provided by Carizzo Marcellus. The pre-drill results indicated no detection of methane. I collected another sample from the residence to determine if the installation of the casing at the well has remediated the problem. I informed Gary Byron, consultant for Carizzo, that I was collecting another sample and of the results of the methane sample.
1950891 Primary Facility 2011-02-18 Routine/Complete Inspection Violation(s) Noted
1954330 Primary Facility 2011-03-03 Follow-up Inspection No Violations Noted
1961133 Primary Facility 2011-03-17 Routine/Complete Inspection No Violations Noted Received and reviewed landowner's requests for restoration plan.
1985100 Primary Facility 2011-06-30 Routine/Complete Inspection No Violations Noted Well has been plugged.
1998265 Primary Facility 2011-08-24 Routine/Complete Inspection No Violations Noted
2005104 Primary Facility 2011-09-26 Administrative/File Review No Violations Noted
2010585 Primary Facility 2011-09-07 Site Restoration Pending
2062442 Primary Facility 2012-04-26 Site Restoration Violation(s) Noted Well was plugged on 2/9/2011 and Drilling Permit had expired on 9/14/2011. The operator has failed to terminate the ESCGP and is in violation of 102.7.
2079799 Primary Facility 2012-06-29 Site Restoration No Viols - Permanently Shut Down Reviewed Well Site Restoration Report.
2526700 Primary Facility 2016-10-11 Administrative/File Review In Compliance with Policy

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1946716 603844 01/26/2011 2011-01-26 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety
1950891 605069 02/18/2011 2011-02-18 102.4NOPLAN - No E&S plan developed, plan not on site Administrative
2062442 637794 04/26/2012 2012-04-26 402CSL B - Failure to meet requirements of permit, rules and regulations, or order of DEP. Environmental Health & Safety NOT requested by 5/18/12. NOT rec'vd 5/14/12, under review for final ok. - Well was plugged oin 2/9/2011 and Drilling Permit had expired on 9/14/2011. The operator has failed to terminate the ESCGP and is in violation of 102.7.

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
637794 283096 NOV - Notice of Violation Administrative Close Out 2012-05-14

For data sources see[7]

References