X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-131-20135

Well Details

Well ID: 37-131-20135
Loading map...
Country: United States
State: Pennsylvania
County: Wyoming
Municipality: Washington Township
Operator Name: BKV OPR LLC
Well Pad ID: 145305
Farm/Lease Name: SOLANICK 1H
License Status:
Spud Date:
Permit Date: 2011-02-08
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.601331
Longitude: -75.973106

For data sources see[1][2][3]

Well History

Date Event
2011-02-08 New Permit Application
2011-03-08 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-04-30 2012-04-30 8,087 4,630,710

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Hydrochloric Acid 10.1-15 Baker Hughes Acidizing Hydrochloric acid 7647-01-0 15.00 0.03
Water 7732-18-5 85.00 0.20
Ingredients shown above are subject
to 29 CFR 1910.1200(i)
and appear on Material
Safety Data Sheets (MSDS). Ingredients shown below are Non-MSDS.
Ferrotrol 300L Baker Hughes Iron Control Citric acid 77-92-9 60.00 0.00290000
Sand, White, 100 mesh Baker Hughes Proppant Quartz 14808-60-7 100.00 0.81
Hydrochloric Acid 5.1-7.5 Baker Hughes Acidizing Water 7732-18-5 92.50 0.92
Hydrochloric acid 7647-01-0 7.50 0.07
Ingredients shown above are subject
to 29 CFR 1910.1200(i)
and appear on Material
Safety Data Sheets (MSDS). Ingredients shown below are Non-MSDS.
Baker Hughes Surfactant Thiourea polymer 68527-49-1
Polyacrylate 0.00301979
Sorbitan Monooleate 0.00443554
Poly (acrylamide-co-acrylic acid) 0.02
Ethoxylated Alcohol 0.00177422
Hydrochloric acid 7647-01-0
Formalin 50-00-0
Sodium chloride 7647-14-5 0.00000453
Salt 0.00443554
Water 7732-18-5 0.06
Potassium chloride 7447-40-7 0.00000755
Water Operator Carrier Water 7732-18-5 100.00 86.91
Alpha 1427 Baker Hughes Biocide Glutaraldehyde 111-30-8 30.00 0.00662000
Ethanol 64-17-5 5.00 0.00110000
Didecyl dimethyl ammonium chloride 7173-51-5 10.00 0.00221000
Quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1 5.00 0.00110000
Sand, White, 30/50 Baker Hughes Proppant Quartz 14808-60-7 100.00 6.22
FRW-18 Baker Hughes Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.02
Sand, White, 40/70 Baker Hughes Proppant Quartz 14808-60-7 100.00 4.64
Scaletrol 720 Baker Hughes Scale Inhibitor Calcium chloride 10043-52-4 5.00 0.00075000
Ethylene glycol 107-21-1 30.00 0.00453000
CI-14 Baker Hughes Corrosion Inhibitor Methanol 67-56-1 100.00 0.00111000
Alkenes, C>10 .alpha.- 64743-02-8 5.00 0.00006000
Ethoxylated C14-15 alcohols 68951-67-7 30.00 0.00033000
Fatty acids, tall-oil 61790-12-3 10.00 0.00011000
Propargyl alcohol 107-19-7 5.00 0.00006000
InFlo 250W Baker Hughes Surfactant 2-Butoxyethanol 111-76-2 5.00 0.00006000
Surfactants 80.00 0.00102000
Methanol 67-56-1 30.00 0.00038000

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CARRIZO (MARCELLUS) LLC 0.00 0 0.00 0 0.00 0
2011 CARRIZO (MARCELLUS) LLC 0.00 0 0.00 0 0.00 0
2012 CARRIZO (MARCELLUS) LLC 191,574.00 61 0.00 0 0.00 0
2013 CARRIZO (MARCELLUS) LLC 1,002,798.00 308 0.00 0 0.00 0
2014 CARRIZO (MARCELLUS) LLC 705,041.65 274 0.00 0 0.00 0
2015 CARRIZO (MARCELLUS) LLC 623,314.78 241 0.00 0 0.00 0
2016 CARRIZO (MARCELLUS) LLC 918,838.67 276 0.00 0 0.00 0
2017 CARRIZO (MARCELLUS) LLC 773,781.68 359 0.00 0 0.00 0
2018 BKV OPR LLC 516,259.38 361 0.00 0 0.00 0
2019 BKV OPR LLC 414,084.11 362 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CARRIZO (MARCELLUS) LLC Drilling Fluid Waste 380.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2011 CARRIZO (MARCELLUS) LLC Drilling Fluid Waste 1,145.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451
2011 CARRIZO (MARCELLUS) LLC Drill Cuttings 414.00 Tons LANDFILL THR029
2011 CARRIZO (MARCELLUS) LLC Drill Cuttings 39.00 Tons LANDFILL 8-0728-0004/013
2011 CARRIZO (MARCELLUS) LLC Drill Cuttings 2,380.00 Tons LANDFILL NY STATE #32S11
2012 CARRIZO (MARCELLUS) LLC Produced Fluid 4,346.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CARRIZO (MARCELLUS) LLC Produced Fluid 3,946.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CARRIZO (MARCELLUS) LLC Produced Fluid 1,032.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE003
2014 CARRIZO (MARCELLUS) LLC Produced Fluid 81.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014 CARRIZO (MARCELLUS) LLC Produced Fluid 22.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE003
2014 CARRIZO (MARCELLUS) LLC Produced Fluid 137.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CARRIZO (MARCELLUS) LLC Produced Fluid 5,563.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014 CARRIZO (MARCELLUS) LLC Produced Fluid 29,053.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 CARRIZO (MARCELLUS) LLC Produced Fluid 148.71 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 CARRIZO (MARCELLUS) LLC Produced Fluid 291.07 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015 CARRIZO (MARCELLUS) LLC Produced Fluid 190.84 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE003
2015 CARRIZO (MARCELLUS) LLC Produced Fluid 1,228.28 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CARRIZO (MARCELLUS) LLC Produced Fluid 101.58 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2016 CARRIZO (MARCELLUS) LLC Produced Fluid 63.24 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE003
2016 CARRIZO (MARCELLUS) LLC Produced Fluid 109.64 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016 CARRIZO (MARCELLUS) LLC Produced Fluid 53.36 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE003
2016 CARRIZO (MARCELLUS) LLC Produced Fluid 187.15 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 CARRIZO (MARCELLUS) LLC Produced Fluid 224.45 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2017 CARRIZO (MARCELLUS) LLC Produced Fluid 241.35 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 CARRIZO (MARCELLUS) LLC Produced Fluid 674.77 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 CARRIZO (MARCELLUS) LLC Produced Fluid 34.80 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2017 CARRIZO (MARCELLUS) LLC Produced Fluid 137.99 Bbl REUSE (AT WELL PAD)
2017 CARRIZO (MARCELLUS) LLC Produced Fluid 371.39 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE003
2018 CARRIZO (MARCELLUS) LLC Produced Fluid 112.55 Bbl REUSE (AT WELL PAD)
2018 CARRIZO (MARCELLUS) LLC Produced Fluid 586.08 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 BKV OPR LLC Produced Fluid 583.75 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 BKV OPR LLC Produced Fluid 53.75 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE003

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1957788 Primary Facility 2011-03-15 Drilling/Alteration No Violations Noted Comp man Jeff Myers H&P 320 Rig closed loop system
1958046 Primary Facility 2011-03-16 Drilling/Alteration No Violations Noted Was on site to watch cement job.
1960282 Primary Facility 2011-03-25 Drilling/Alteration No Violations Noted proposed depth is 7500' on air, just moved back on from 2H this morning, didn,t go near rig- testing BOP to 5000 psi
1961819 Primary Facility 2011-03-30 Drilling/Alteration No Violations Noted Mud logger not here, didn't check log book
1964432 Primary Facility 2011-04-07 Drilling/Alteration Pending H&P Flex Rig 320 @ 5593' w/ oil based mud
1964801 Primary Facility 2011-04-11 Follow-up Inspection No Violations Noted checked drillers log- good
1966447 Primary Facility 2011-04-18 Drilling/Alteration No Violations Noted drillers log checked at TD - 13460'
1967734 Primary Facility 2011-04-22 Drilling/Alteration No Violations Noted done drilling, just reporting cement info.
1990336 Primary Facility 2011-07-15 Routine/Complete Inspection Violation(s) Noted No well identification.
2002575 Primary Facility 2011-09-12 Routine/Complete Inspection Pending Cellars full of water. Didn't see well tags? Extreme bubbling in 2 wells w/ lesser amount in 3rd. Took video. May be from prod csg, but can't tell. Will need to get pump truck and identify if it is gas and where it is coming from.
2003154 Primary Facility 2011-09-14 Follow-up Inspection No Violations Noted Cellars were full of water - bubbling so follow up - checking where bubbles were coming from. In all cases - from 5 1/2 X 9 5/8" annulus vent. No bubbles from 9 5/8 X 13 3/8" or 13 3/8 X 20" or outside 20"
2083738 Primary Facility 2012-07-10 Routine/Complete Inspection No Violations Noted During the investigation, I used an Extech, ExStik (2) pH, Conductivity, Salinty and TDS meter to field screen ponded water inside the duck pond type containment area where a pump was located and the secondary containment for the frac tanks. I also screened an area outside the containment area on the Well Pad close to where pump and filtration system are located. Conductivity readings indicated over the limit inside the duck type containment area and the area of ponded water on the Well Pad I mentioned above. The limit on the meter is 19.99 milliSiemens/cm.
2085662 Primary Facility 2012-07-11 Follow-up Inspection No Violations Noted During the investigation, I used an Extech, ExStik (2) pH, Conductivity, Salinty and TDS meter to field screen a small area of ponded water outside the containment area on the Well Pad close to where pump and filtration system are located. Conductivity readings indicated over the limit with the limit on the meter being 19.99 milliSiemens/cm. During the inspection a vaccuum truck mobilized to the site and began to remove the ponded water on the Well Pad from the site. The Department recommended that Carrizo remove the whitish precipitate/residue on the Well Pad, repair any areas of the secondary contaiment liner experiencing compromised integrity and re-position the gas buster tanks prior to the commencement of flowback.
2086417 Primary Facility 2012-07-16 Follow-up Inspection No Violations Noted During the inspection, Carrizo was in the process of gas flaring and flowback and filtration of the wells at the site.
2164798 Primary Facility 2013-05-01 Routine/Partial Inspection No Violations Noted Related to Mazzara Incident: 2162665
2164803 Primary Facility 2013-05-07 Follow-up Inspection Pending
2341060 Primary Facility 2015-02-04 Routine/Partial Inspection No Violations Noted
2599891 Primary Facility 2017-05-19 Routine/Partial Inspection No Violations Noted JP Reilly on site greasing ball valves.
2726378 Primary Facility 2018-05-03 Routine/Complete Inspection No Violations Noted I conducted the inspection accompanied by Casey Baldwin (WQS/ET). A Vacuum Truck was emptying stormwater that had accumulated in the Production Fluid Storage Tank containment. There were no violations noted. If you have any questions, please contact me.
2726633 Primary Facility 2018-05-03 Routine/Complete Inspection No Violations Noted I conducted the inspection accompanied by Casey Baldwin (WQS/ET). A Vacuum Truck was emptying stormwater that had accumulated in the Production Fluid Storage Tank containment. There were no violations noted. If you have any questions, please contact me.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1990336 616171 07/15/2011 2011-07-15 201TAG - Failure to install, in a permanent manner, the permit number on a completed well Administrative

For data sources see[8]

References