If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-131-20135 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.601331,"lon":-75.973106,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Wyoming | |
Municipality: Washington Township | |
Operator Name: BKV OPR LLC | |
Well Pad ID: 145305 | |
Farm/Lease Name: SOLANICK 1H | |
License Status: | |
Spud Date: | |
Permit Date: 2011-02-08 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.601331 | |
Longitude: -75.973106 |
Date | Event |
---|---|
2011-02-08 | New Permit Application |
2011-03-08 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-04-30 | 2012-04-30 | 8,087 | 4,630,710 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Hydrochloric Acid 10.1-15 | Baker Hughes | Acidizing | Hydrochloric acid | 7647-01-0 | 15.00 | 0.03 | |
Water | 7732-18-5 | 85.00 | 0.20 | |||||
Ingredients shown above are subject to 29 CFR 1910.1200(i) and appear on Material Safety Data Sheets (MSDS). Ingredients shown below are Non-MSDS. |
||||||||
Ferrotrol 300L | Baker Hughes | Iron Control | Citric acid | 77-92-9 | 60.00 | 0.00290000 | ||
Sand, White, 100 mesh | Baker Hughes | Proppant | Quartz | 14808-60-7 | 100.00 | 0.81 | ||
Hydrochloric Acid 5.1-7.5 | Baker Hughes | Acidizing | Water | 7732-18-5 | 92.50 | 0.92 | ||
Hydrochloric acid | 7647-01-0 | 7.50 | 0.07 | |||||
Ingredients shown above are subject to 29 CFR 1910.1200(i) and appear on Material Safety Data Sheets (MSDS). Ingredients shown below are Non-MSDS. |
Baker Hughes | Surfactant | Thiourea polymer | 68527-49-1 | ||||
Polyacrylate | 0.00301979 | |||||||
Sorbitan Monooleate | 0.00443554 | |||||||
Poly (acrylamide-co-acrylic acid) | 0.02 | |||||||
Ethoxylated Alcohol | 0.00177422 | |||||||
Hydrochloric acid | 7647-01-0 | |||||||
Formalin | 50-00-0 | |||||||
Sodium chloride | 7647-14-5 | 0.00000453 | ||||||
Salt | 0.00443554 | |||||||
Water | 7732-18-5 | 0.06 | ||||||
Potassium chloride | 7447-40-7 | 0.00000755 | ||||||
Water | Operator | Carrier | Water | 7732-18-5 | 100.00 | 86.91 | ||
Alpha 1427 | Baker Hughes | Biocide | Glutaraldehyde | 111-30-8 | 30.00 | 0.00662000 | ||
Ethanol | 64-17-5 | 5.00 | 0.00110000 | |||||
Didecyl dimethyl ammonium chloride | 7173-51-5 | 10.00 | 0.00221000 | |||||
Quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | 5.00 | 0.00110000 | |||||
Sand, White, 30/50 | Baker Hughes | Proppant | Quartz | 14808-60-7 | 100.00 | 6.22 | ||
FRW-18 | Baker Hughes | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.02 | ||
Sand, White, 40/70 | Baker Hughes | Proppant | Quartz | 14808-60-7 | 100.00 | 4.64 | ||
Scaletrol 720 | Baker Hughes | Scale Inhibitor | Calcium chloride | 10043-52-4 | 5.00 | 0.00075000 | ||
Ethylene glycol | 107-21-1 | 30.00 | 0.00453000 | |||||
CI-14 | Baker Hughes | Corrosion Inhibitor | Methanol | 67-56-1 | 100.00 | 0.00111000 | ||
Alkenes, C>10 .alpha.- | 64743-02-8 | 5.00 | 0.00006000 | |||||
Ethoxylated C14-15 alcohols | 68951-67-7 | 30.00 | 0.00033000 | |||||
Fatty acids, tall-oil | 61790-12-3 | 10.00 | 0.00011000 | |||||
Propargyl alcohol | 107-19-7 | 5.00 | 0.00006000 | |||||
InFlo 250W | Baker Hughes | Surfactant | 2-Butoxyethanol | 111-76-2 | 5.00 | 0.00006000 | ||
Surfactants | 80.00 | 0.00102000 | ||||||
Methanol | 67-56-1 | 30.00 | 0.00038000 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | CARRIZO (MARCELLUS) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | CARRIZO (MARCELLUS) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CARRIZO (MARCELLUS) LLC | 191,574.00 | 61 | 0.00 | 0 | 0.00 | 0 |
2013 | CARRIZO (MARCELLUS) LLC | 1,002,798.00 | 308 | 0.00 | 0 | 0.00 | 0 |
2014 | CARRIZO (MARCELLUS) LLC | 705,041.65 | 274 | 0.00 | 0 | 0.00 | 0 |
2015 | CARRIZO (MARCELLUS) LLC | 623,314.78 | 241 | 0.00 | 0 | 0.00 | 0 |
2016 | CARRIZO (MARCELLUS) LLC | 918,838.67 | 276 | 0.00 | 0 | 0.00 | 0 |
2017 | CARRIZO (MARCELLUS) LLC | 773,781.68 | 359 | 0.00 | 0 | 0.00 | 0 |
2018 | BKV OPR LLC | 516,259.38 | 361 | 0.00 | 0 | 0.00 | 0 |
2019 | BKV OPR LLC | 414,084.11 | 362 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | CARRIZO (MARCELLUS) LLC | Drilling Fluid Waste | 380.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0102784 |
2011 | CARRIZO (MARCELLUS) LLC | Drilling Fluid Waste | 1,145.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 |
2011 | CARRIZO (MARCELLUS) LLC | Drill Cuttings | 414.00 Tons | LANDFILL | THR029 |
2011 | CARRIZO (MARCELLUS) LLC | Drill Cuttings | 39.00 Tons | LANDFILL | 8-0728-0004/013 |
2011 | CARRIZO (MARCELLUS) LLC | Drill Cuttings | 2,380.00 Tons | LANDFILL | NY STATE #32S11 |
2012 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 4,346.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 3,946.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 1,032.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 81.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 22.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 137.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 5,563.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 29,053.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 148.71 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 291.07 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 190.84 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 1,228.28 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 101.58 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 63.24 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 109.64 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 53.36 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 187.15 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 224.45 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 241.35 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 674.77 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 34.80 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 137.99 Bbl | REUSE (AT WELL PAD) | |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 371.39 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2018 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 112.55 Bbl | REUSE (AT WELL PAD) | |
2018 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 586.08 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | BKV OPR LLC | Produced Fluid | 583.75 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | BKV OPR LLC | Produced Fluid | 53.75 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1957788 | Primary Facility | 2011-03-15 | Drilling/Alteration | No Violations Noted | Comp man Jeff Myers H&P 320 Rig closed loop system |
1958046 | Primary Facility | 2011-03-16 | Drilling/Alteration | No Violations Noted | Was on site to watch cement job. |
1960282 | Primary Facility | 2011-03-25 | Drilling/Alteration | No Violations Noted | proposed depth is 7500' on air, just moved back on from 2H this morning, didn,t go near rig- testing BOP to 5000 psi |
1961819 | Primary Facility | 2011-03-30 | Drilling/Alteration | No Violations Noted | Mud logger not here, didn't check log book |
1964432 | Primary Facility | 2011-04-07 | Drilling/Alteration | Pending | H&P Flex Rig 320 @ 5593' w/ oil based mud |
1964801 | Primary Facility | 2011-04-11 | Follow-up Inspection | No Violations Noted | checked drillers log- good |
1966447 | Primary Facility | 2011-04-18 | Drilling/Alteration | No Violations Noted | drillers log checked at TD - 13460' |
1967734 | Primary Facility | 2011-04-22 | Drilling/Alteration | No Violations Noted | done drilling, just reporting cement info. |
1990336 | Primary Facility | 2011-07-15 | Routine/Complete Inspection | Violation(s) Noted | No well identification. |
2002575 | Primary Facility | 2011-09-12 | Routine/Complete Inspection | Pending | Cellars full of water. Didn't see well tags? Extreme bubbling in 2 wells w/ lesser amount in 3rd. Took video. May be from prod csg, but can't tell. Will need to get pump truck and identify if it is gas and where it is coming from. |
2003154 | Primary Facility | 2011-09-14 | Follow-up Inspection | No Violations Noted | Cellars were full of water - bubbling so follow up - checking where bubbles were coming from. In all cases - from 5 1/2 X 9 5/8" annulus vent. No bubbles from 9 5/8 X 13 3/8" or 13 3/8 X 20" or outside 20" |
2083738 | Primary Facility | 2012-07-10 | Routine/Complete Inspection | No Violations Noted | During the investigation, I used an Extech, ExStik (2) pH, Conductivity, Salinty and TDS meter to field screen ponded water inside the duck pond type containment area where a pump was located and the secondary containment for the frac tanks. I also screened an area outside the containment area on the Well Pad close to where pump and filtration system are located. Conductivity readings indicated over the limit inside the duck type containment area and the area of ponded water on the Well Pad I mentioned above. The limit on the meter is 19.99 milliSiemens/cm. |
2085662 | Primary Facility | 2012-07-11 | Follow-up Inspection | No Violations Noted | During the investigation, I used an Extech, ExStik (2) pH, Conductivity, Salinty and TDS meter to field screen a small area of ponded water outside the containment area on the Well Pad close to where pump and filtration system are located. Conductivity readings indicated over the limit with the limit on the meter being 19.99 milliSiemens/cm. During the inspection a vaccuum truck mobilized to the site and began to remove the ponded water on the Well Pad from the site. The Department recommended that Carrizo remove the whitish precipitate/residue on the Well Pad, repair any areas of the secondary contaiment liner experiencing compromised integrity and re-position the gas buster tanks prior to the commencement of flowback. |
2086417 | Primary Facility | 2012-07-16 | Follow-up Inspection | No Violations Noted | During the inspection, Carrizo was in the process of gas flaring and flowback and filtration of the wells at the site. |
2164798 | Primary Facility | 2013-05-01 | Routine/Partial Inspection | No Violations Noted | Related to Mazzara Incident: 2162665 |
2164803 | Primary Facility | 2013-05-07 | Follow-up Inspection | Pending | |
2341060 | Primary Facility | 2015-02-04 | Routine/Partial Inspection | No Violations Noted | |
2599891 | Primary Facility | 2017-05-19 | Routine/Partial Inspection | No Violations Noted | JP Reilly on site greasing ball valves. |
2726378 | Primary Facility | 2018-05-03 | Routine/Complete Inspection | No Violations Noted | I conducted the inspection accompanied by Casey Baldwin (WQS/ET). A Vacuum Truck was emptying stormwater that had accumulated in the Production Fluid Storage Tank containment. There were no violations noted. If you have any questions, please contact me. |
2726633 | Primary Facility | 2018-05-03 | Routine/Complete Inspection | No Violations Noted | I conducted the inspection accompanied by Casey Baldwin (WQS/ET). A Vacuum Truck was emptying stormwater that had accumulated in the Production Fluid Storage Tank containment. There were no violations noted. If you have any questions, please contact me. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1990336 | 616171 | 07/15/2011 | 2011-07-15 | 201TAG - Failure to install, in a permanent manner, the permit number on a completed well | Administrative |
For data sources see[8]