If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-131-20145 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.608564,"lon":-75.973272,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Wyoming | |
Municipality: Washington Township | |
Operator Name: BKV OPR LLC | |
Well Pad ID: 145313 | |
Farm/Lease Name: SICKLER 3H | |
License Status: | |
Spud Date: 2011-04-22 | |
Permit Date: 2011-03-22 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.608564 | |
Longitude: -75.973272 |
Date | Event |
---|---|
2011-03-22 | New Permit Application |
2011-03-28 | Performed Spud Operation |
2011-10-02 | Drilling Completion |
2012-03-05 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-06-28 | 2012-06-28 | 7,937 | 7,250,754 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Scaletrol 720 | Baker Hughes | Scale Inhibitor | Calcium chloride | 10043-52-4 | 5.00 | 0.00077000 | |
Ethylene glycol | 107-21-1 | 30.00 | 0.00460000 | |||||
CI-14 | Baker Hughes | Corrosion Inhibitor | Alkenes, C>10 .alpha.- | 64743-02-8 | 5.00 | 0.00005000 | ||
Methanol | 67-56-1 | 100.00 | 0.00103000 | |||||
Fatty acids, tall-oil | 61790-12-3 | 10.00 | 0.00010000 | |||||
Propargyl alcohol | 107-19-7 | 5.00 | 0.00005000 | |||||
Ethoxylated C14-15 alcohols | 68951-67-7 | 30.00 | 0.00031000 | |||||
Hydrochloric Acid 5.1-7.5 | Baker Hughes | Acidizing | Water | 7732-18-5 | 92.50 | 0.85 | ||
Hydrochloric acid | 7647-01-0 | 7.50 | 0.06 | |||||
FRW-18 | Baker Hughes | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.02 | ||
Sand, White, 30/50 | Baker Hughes | Proppant | Quartz | 14808-60-7 | 100.00 | 5.54 | ||
Ferrotrol 300L | Baker Hughes | Iron Control | Citric acid | 77-92-9 | 60.00 | 0.00270000 | ||
Sand, White, 100 mesh | Baker Hughes | Proppant | Quartz | 14808-60-7 | 100.00 | 0.78 | ||
Alpha 1427 | Baker Hughes | Biocide | Ethanol | 64-17-5 | 5.00 | 0.00112000 | ||
Quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | 5.00 | 0.00112000 | |||||
Didecyl dimethyl ammonium chloride | 7173-51-5 | 10.00 | 0.00223000 | |||||
Glutaraldehyde | 111-30-8 | 30.00 | 0.00670000 | |||||
Ingredients shown above are subject to 29 CFR 1910.1200(i) and appear on Material Safety Data Sheets (MSDS). Ingredients shown below are Non-MSDS. |
Baker Hughes | Surfactant | Sodium chloride | 7647-14-5 | 0.00000460 | |||
Hydrochloric acid | 7647-01-0 | |||||||
Ethoxylated Alcohol | 0.00179945 | |||||||
Potassium chloride | 7447-40-7 | 0.00000767 | ||||||
Water | 7732-18-5 | 0.06 | ||||||
Salt | 0.00449862 | |||||||
Polyacrylate | 0.00306917 | |||||||
Sorbitan Monooleate | 0.00449862 | |||||||
Formalin | 50-00-0 | |||||||
Poly (acrylamide-co-acrylic acid) | 0.02 | |||||||
Thiourea polymer | 68527-49-1 | |||||||
Water | Operator | Carrier | Water | 7732-18-5 | 100.00 | 87.96 | ||
InFlo 250W | Baker Hughes | Surfactant | Surfactants | 80.00 | 0.00095000 | |||
2-Butoxyethanol | 111-76-2 | 5.00 | 0.00006000 | |||||
Methanol | 67-56-1 | 30.00 | 0.00036000 | |||||
Hydrochloric Acid 10.1-15 | Baker Hughes | Acidizing | Water | 7732-18-5 | 85.00 | 0.19 | ||
Hydrochloric acid | 7647-01-0 | 15.00 | 0.03 | |||||
Ingredients shown above are subject to 29 CFR 1910.1200(i) and appear on Material Safety Data Sheets (MSDS). Ingredients shown below are Non-MSDS. |
||||||||
Sand, White, 40/70 | Baker Hughes | Proppant | Quartz | 14808-60-7 | 100.00 | 4.39 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | CARRIZO (MARCELLUS) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CARRIZO (MARCELLUS) LLC | 411,075.00 | 61 | 0.00 | 0 | 0.00 | 0 |
2013 | CARRIZO (MARCELLUS) LLC | 1,777,758.00 | 249 | 0.00 | 0 | 0.00 | 0 |
2014 | CARRIZO (MARCELLUS) LLC | 1,788,899.61 | 316 | 0.00 | 0 | 0.00 | 0 |
2015 | CARRIZO (MARCELLUS) LLC | 733,890.10 | 171 | 0.00 | 0 | 0.00 | 0 |
2016 | CARRIZO (MARCELLUS) LLC | 499,934.10 | 110 | 0.00 | 0 | 0.00 | 0 |
2017 | CARRIZO (MARCELLUS) LLC | 1,900,133.93 | 356 | 0.00 | 0 | 0.00 | 0 |
2018 | BKV OPR LLC | 1,305,241.94 | 364 | 0.00 | 0 | 0.00 | 0 |
2019 | BKV OPR LLC | 1,139,881.10 | 362 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | CARRIZO (MARCELLUS) LLC | Drill Cuttings | 5.00 Tons | LANDFILL | THR029 |
2011 | CARRIZO (MARCELLUS) LLC | Drill Cuttings | 812.00 Tons | LANDFILL | NY STATE #32S11 |
2012 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 1,324.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 2,447.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 901.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 320.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 200.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW018 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 132.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 605.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | CARRIZO (MARCELLUS) LLC | Basic Sediment | 62.70 Bbl | LANDFILL | THR029 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 542.23 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 0.91 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 313.43 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 273.32 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 928.60 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 71.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 24.30 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 48.01 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Basic Sediment | 12.14 Bbl | LANDFILL | THR029 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 34.58 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 226.23 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 271.76 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 29.26 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 53.87 Bbl | REUSE (AT WELL PAD) | |
2017 | CARRIZO (MARCELLUS) LLC | Other Oil & Gas Wastes | 1.03 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2018 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 337.16 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 91.35 Bbl | REUSE (AT WELL PAD) | |
2019 | BKV OPR LLC | Synthetic Liner Materials | 0.29 Tons | ||
2019 | BKV OPR LLC | Synthetic Liner Materials | 0.29 Tons | BENEFICIAL REUSE ?PERMIT | |
2019 | BKV OPR LLC | Produced Fluid | 401.82 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | BKV OPR LLC | Produced Fluid | 10.83 Bbl | REUSE (AT WELL PAD) | |
2019 | BKV OPR LLC | Synthetic Liner Materials | 1.26 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101714 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1962570 | Primary Facility | 2011-04-01 | Drilling/Alteration | No Violations Noted | hole wet from 40' - 60' |
1972468 | Primary Facility | 2011-05-11 | Drilling/Alteration | No Violations Noted | waiting on cement -done at 9:30 PM, moving rig to Sickler 2H |
1975610 | Primary Facility | 2011-05-09 | Drilling/Alteration | No Violations Noted | FAlcon 14 Company man Wayne Simon air drilling |
2001929 | Primary Facility | 2011-09-06 | Drilling/Alteration | No Violations Noted | H&P 320 Flex rig Comp. Man- Dwain Davis |
2001934 | Primary Facility | 2011-09-12 | Drilling/Alteration | No Violations Noted | H&P 320 Flex rig Comp. Man - Dwain Davis |
2002542 | Primary Facility | 2011-09-14 | Drilling/Alteration | No Violations Noted | H&G 320, Comp. Man - John Savage, drilling @ 11478' |
2004588 | Primary Facility | 2011-09-20 | Drilling/Alteration | No Violations Noted | H&P 320, Comp. Man - John Savage |
2005313 | Primary Facility | 2011-09-26 | Drilling/Alteration | No Violations Noted | drilled to 14714'. Been stuck since Friday, were coming out of hole, can't move, can't circ., using tractor on wireline. (Express Energy Sources), will try to get down to bit, then perf and try to circ, may shoot off bit. |
2007028 | Primary Facility | 2011-09-29 | Drilling/Alteration | No Violations Noted | H&P 320, Comp. Man - John Savage |
2029522 | Primary Facility | 2011-12-27 | Routine/Complete Inspection | No Violations Noted | |
2080488 | Primary Facility | 2012-06-26 | Routine/Complete Inspection | No Violations Noted | Chris Kyea - Comp. Man |
2104533 | Primary Facility | 2012-10-01 | Follow-up Inspection | No Violations Noted | Met Gary Byron, Tom Weller, & Jesse Bonnice on site to flood cellar and check for annular gas. No gas was detected. |
2341044 | Primary Facility | 2015-02-04 | Routine/Partial Inspection | No Violations Noted | |
2382660 | Primary Facility | 2015-06-26 | Routine/Partial Inspection | No Violations Noted | |
2426461 | Primary Facility | 2015-11-09 | Routine/Complete Inspection | No Violations Noted | |
2489929 | Primary Facility | 2016-05-31 | Administrative/File Review | No Violations Noted | The Department has reviewed the remediation summary report and determined that the remediation of the impacted area of the pad surface associated with the production fluid spill is adequate. No further action is warranted of Carrizo at this time. |
2537139 | Primary Facility | 2016-11-15 | Routine/Partial Inspection | No Violations Noted | |
2537144 | Primary Facility | 2016-11-15 | Routine/Partial Inspection | No Violations Noted | |
2599669 | Primary Facility | 2017-05-19 | Routine/Partial Inspection | No Violations Noted | |
2641315 | Primary Facility | 2017-09-14 | Routine/Partial Inspection | No Violations Noted | There was no activity occurring at the site during the inspection. There were no violations noted. If you have any questions, please contact me. |
2661526 | Primary Facility | 2017-11-06 | Routine/Complete Inspection | No Violations Noted | Arrived on location to perform routine inspection and update status of wells. 6 wells on location. 6 treaters, 6 separators and 4 tanks. All cellars filled with water with no apparent bubbling. Prod casing pressures are as follows: 1H = 500psi, 2H = 500psi, 3 = 600psi, 4 = 400psi, 5 = 600psi, 6 = 500psi. No issues or concerns at time of inspection. |
For data sources see[8]