Well Details

Well ID: 37-131-20237
Loading map...
Country: United States
State: Pennsylvania
County: Wyoming
Municipality: Washington Township
Operator Name: BKV OPR LLC
Well Pad ID: 149169
Farm/Lease Name: REEL UNIT MACIALEK 1 REEL 1H
License Status:
Spud Date: 2013-01-13
Permit Date: 2012-01-31
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.578709
Longitude: -75.989159

For data sources see[1][2][3]

Well History

Date Event
2012-01-31 New Permit Application
2013-01-09 Performed Spud Operation
2013-12-20 New Permit Application
2014-02-27 Drilling Completion
2014-03-21 Perforation
2014-03-21 Performed Stimulation
2015-11-09 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-03-21 2014-03-29 7,791 7,279,060

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand FTS Proppant Silica 14808-60-7 99.9 13.3066 0
Water FTS carrier H2O 7732-18-5 100 85.737 0
ICI-3240 FTS Bacteriacide Dazomet 533-74-4 24 0.007596 0
Sodium Hydroxide 1310-73-2 4 0.001266 0
HCL FTS Acid Hydrochloric acid 7647-01-0 37 0.313782 0
CS 500SI FTS Scale Inhibitor Ethylene Glycol 107-21-1 10 0.001728 0
FRW-600 FTS Friction Reducer Ammonium acetate 631-61-8 6 0.002454 0
Hydrotreated Light Distillate 64742-47-8 30 0.012272 0
CI-150 FTS Acid Corrosion Inhibitor Dimethylformamide 68-12-2 10 0.000509 0
Quanternary ammonium compound Proprietary 10 0.000509 0
Isopropanol 67-63-0 30 0.001527 0
Aromatic aldehyde Proprietary 10 0.000509 0
Ethylene Glycol 107-21-1 30 0.001527 0
Organice amine resin Proprietary 30 0.001527 0

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-03-21 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CITRUS ENERGY CORP 0.00 0 0.00 0 0.00 0
2012 CITRUS ENERGY CORP 0.00 0 0.00 0 0.00 0
2013 CITRUS ENERGY CORP 0.00 0 0.00 0 0.00 0
2014 WARREN E & P INC 246,654.58 204 0.00 0 0.00 0
2015 WARREN E & P INC 354,945.36 360 0.00 0 0.00 0
2016 WARREN E & P INC 277,395.28 366 0.00 0 0.00 0
2017 WARREN E & P INC 274,499.78 364 0.00 0 0.00 0
2018 BKV OPR LLC 239,108.72 345 0.00 0 0.00 0
2019 BKV OPR LLC 231,887.74 364 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 CITRUS ENERGY CORP Drill Cuttings 1,453.00 Tons LANDFILL THR029
2014 CITRUS ENERGY CORP Fracturing Fluid Waste 26.00 Tons LANDFILL THR029
2014 CITRUS ENERGY CORP Produced Fluid 2,437.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 WARREN E & P INC Produced Fluid 11,022.70 Bbl STORAGE PENDING DISPOSAL OR REUSE
2015 WARREN E & P INC Produced Fluid 2,370.46 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015 WARREN E & P INC Produced Fluid 10,347.70 Bbl STORAGE PENDING DISPOSAL OR REUSE
2016 WARREN E & P INC Other Oil & Gas Wastes 22.77 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016 WARREN E & P INC Produced Fluid 3,392.59 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016 WARREN E & P INC Produced Fluid 241.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2016 WARREN E & P INC Other Oil & Gas Wastes 11.81 Bbl STORAGE PENDING DISPOSAL OR REUSE
2016 WARREN E & P INC Other Oil & Gas Wastes 20.53 Tons LANDFILL THR029
2016 WARREN E & P INC Other Oil & Gas Wastes 139.34 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2016 WARREN E & P INC Produced Fluid 2,875.76 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2016 WARREN E & P INC Produced Fluid 1,103.11 Bbl STORAGE PENDING DISPOSAL OR REUSE
2016 WARREN E & P INC Produced Fluid 110.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 WARREN E & P INC Produced Fluid 2,648.44 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 WARREN E & P INC Produced Fluid 166.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2017 WARREN E & P INC Produced Fluid 1,301.45 Bbl REUSE (AT WELL PAD)
2017 WARREN E & P INC Other Oil & Gas Wastes 64.75 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018 BKV OPR LLC Produced Fluid 108.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE003
2018 WARREN E & P INC Produced Fluid 390.35 Bbl REUSE (AT WELL PAD)
2018 WARREN E & P INC Other Oil & Gas Wastes 34.80 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018 BKV OPR LLC Waste Water Treatment Sludge 0.25 Tons RESIDUAL WASTE PROCESSING FACILITY 301333
2018 WARREN E & P INC Produced Fluid 3,746.45 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 BKV OPR LLC Produced Fluid 166.00 Bbl REUSE (AT WELL PAD)
2019 BKV OPR LLC Produced Fluid 107.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE003
2019 BKV OPR LLC Produced Fluid 3,566.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2133600 Primary Facility 2013-01-25 Drilling/Alteration Pending No one on site. 2 half rounds (empty) and backhoe on site. Cond and rathole complete, but cellar is not dug out.
2165710 Primary Facility 2013-05-13 Routine/Complete Inspection No Violations Noted
2243432 Primary Facility 2014-02-06 Drilling/Alteration No Violations Noted Precision 528, Comp Man - Jake Oetel, @ 2750'
2247735 Primary Facility 2014-02-21 Drilling/Alteration No Violations Noted Precision 528, Comp Man - Jay Lewis, @ 12915' TD
2264409 Primary Facility 2014-04-09 Routine/Complete Inspection No Violations Noted Flowback procedures were in progress for the Reel Unit Macialek 1 Reel 1H well. The Macialek Unit Macialek 1 1H well is in production. Flowback procedures commenced on 4/7/14 according to Citrus. The flowback process has not returned any gas to the surface as of yet. An in line heater, separation unit and gas buster tank staged on secondary containment are utilized for the flowback process. Flowback water is transferred to frac tanks in the frac tank battery on location next to the Pad berm. According to Citrus, most of the frac tanks are empty. Upon filling the tanks with flowback water, the tanks will be transported to the P&G (5) Well Pad for reuse as well stimulation procedures are on-going for the PREVOST UNIT P&G 5 PREVOST 1H and RUARK UNIT P&G 5 RUARK 4H wells. There were some areas of compromised integrity in the frac tank battery secondary containment system.
2331139 Primary Facility 2014-12-23 Routine/Partial Inspection No Violations Noted
2427401 Primary Facility 2015-11-17 Routine/Complete Inspection No Violations Noted Conducted an investigation of the collected stormwater to determine the composition of fluid found in containment of Production Fluid Storage Area. Field analysis of stormwater measured 500 microSiemens in containment area. A sample of the accumulated storm water was collected for Sample Suite 046 (3809-117)
2744897 Primary Facility 2018-06-13 Routine/Complete Inspection No Violations Noted I arrived at the site at 13:43. The weather conditions are cloudy skies with light winds and temperatures around 70 degrees Fahrenheit. There was no activity or personnel at the site. The Macialek 1H and Macialek- Reel 1H wells are in the production phase of operations. A service rig performing similar workover operations on the Ruark South Pad, has recently moved off this location according to Reilly and BKV personnel during the Department's inspection at the BKV Ruark South Pad on 6/13/18, inspection ID# 2743281. The secondary containment dedicated for work-over operations remains in place. A frac tank most likely containing production fluid generated from BKV wells and used during the work-over process, also remains in place. I observed a petroleum sheen on containment near the Macialek Reel 1H well. I used a blue Hanna HI 9831 Soil Test EC & Temperature meter, and white Hanna HI 9831 Groline Soil Test meter to conduct field screening of specific conductance (conductivity) of water on secondary
2754150 Primary Facility 2018-07-10 Follow-up Inspection No Violations Noted Matt Shope, DEP O&G WQS and I arrived at the site at 12:08 to conduct a follow-up inspection. The weather conditions are mostly sunny skies, warm and humid, with light winds and temperatures in the mid 80's. There was no activity or personnel at the site during the inspection. The most recent inspection conducted by the Department was on 6/13/18. During the 6/13/18 inspection, I discovered a petroleum sheen on the secondary containment near the wellheads, along with elevated conductivity readings in water in containment near the wellheads and containment unit for a frac tank. For additional details refer to the Department's 6-13-18 inspection report, inspection ID # 2744324. The frac tank and secondary containment have been removed from the site. Conductivity levels were elevated in water in the production fluid tanks containment unit and in the Macialek-Reel 1H well cellar. See photos. The Department left the site at 12:59.

For data sources see[9]