If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-131-20260 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.625031,"lon":-75.938039,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Wyoming | |
Municipality: Lemon Township | |
Operator Name: CHIEF OIL & GAS LLC | |
Well Pad ID: 145704 | |
Farm/Lease Name: GARRISON NORTH UNIT 3H | |
License Status: | |
Spud Date: 2013-07-24 | |
Permit Date: 2013-01-14 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.625031 | |
Longitude: -75.938039 |
Date | Event |
---|---|
2013-01-14 | New Permit Application |
2013-07-03 | Performed Spud Operation |
2013-08-10 | Drilling Completion |
2014-01-27 | Perforation |
2014-03-17 | Performed Stimulation |
2014-08-21 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2014-03-17 | 2014-03-24 | 7,705 | 10,126,300 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Hydrochloric Acid 10-30% | Halliburton | Acid | Hydrochloric Acid | 7647-01-0 | 30 | 0.08 | 0 |
BA-40L | Halliburton | Buffering Agent | Potassium Carbonate | 584-08-7 | 60 | 0.0003 | 0 | |
MCS-2510T | MULTI-CHEM | Scale Inhibitor | ETHYLENE GLYCOL | 107-21-1 | 60 | 0.005 | 0 | |
FR-66 | Halliburton | Friction Reducer | Hydrotreated Light Petroleum Distillate | 64742-47-8 | 30 | 0.03 | 0 | |
MCB-8614 | MULTI-CHEM | BIOCIDE | GLUTARALDEHYDE | 111-30-8 | 30 | 0.02 | 0 | |
ALKYL (C12-16) DIMETHYLBENZXYLAMMONIUM CHLORIDE | 68424-85-1 | 5 | 0.003 | 0 | ||||
Water | Provided by Customer | Base Fluid | Fresh Water | 0000-00-0 | 100 | 99.87 | 0 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2014-03-17 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2013 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | CHIEF OIL & GAS LLC | 1,687,231.00 | 182 | 0.00 | 0 | 0.00 | 0 |
2015 | CHIEF OIL & GAS LLC | 2,264,090.76 | 259 | 0.00 | 0 | 0.00 | 0 |
2016 | CHIEF OIL & GAS LLC | 2,883,626.91 | 363 | 0.00 | 0 | 0.00 | 0 |
2017 | CHIEF OIL & GAS LLC | 1,185,293.35 | 360 | 0.00 | 0 | 0.00 | 0 |
2018 | CHIEF OIL & GAS LLC | 1,029,213.64 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CHIEF OIL & GAS LLC | 873,039.56 | 363 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2013 | CHIEF OIL & GAS LLC | Drill Cuttings | 2,382.93 Tons | LANDFILL | 100933 |
2014 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 216.88 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2014 | CHIEF OIL & GAS LLC | Produced Fluid | 5,458.29 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 3,036.57 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | CHIEF OIL & GAS LLC | Produced Fluid | 685.23 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 1,260.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2016 | CHIEF OIL & GAS LLC | Produced Fluid | 928.36 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 60.94 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 95.19 Bbl | REUSE (AT WELL PAD) | |
2018 | CHIEF OIL & GAS LLC | Produced Fluid | 253.64 Bbl | REUSE (AT WELL PAD) | |
2019 | CHIEF OIL & GAS LLC | Produced Fluid | 232.58 Bbl | REUSE (AT WELL PAD) |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2181693 | Primary Facility | 2013-07-09 | Routine/Complete Inspection | No Violations Noted | |
2185627 | Primary Facility | 2013-07-23 | Drilling/Alteration | No Violations Noted | drilling at 6724 300 to the curve and oil based mud cement info hrd cpy |
2185798 | Primary Facility | 2013-07-05 | Drilling/Alteration | No Violations Noted | Ziengenfuss on site drilling. Will try to get 60', but in hard sandstone. No water. |
2187919 | Primary Facility | 2013-07-31 | Routine/Complete Inspection | Viol(s) Noted & Immediately Corrected | |
2188715 | Primary Facility | 2013-07-31 | Drilling/Alteration | Pending | Patterson 254, Comp. Man - Rafael Vales @ 11,448' |
2211943 | Primary Facility | 2013-10-08 | Follow-up Inspection | No Violations Noted | Received and reviewed sample analysis. |
2505879 | Primary Facility | 2016-07-27 | Routine/Complete Inspection | No Violations Noted | |
2546009 | Primary Facility | 2016-12-19 | Routine/Complete Inspection | No Violations Noted | |
2713317 | Primary Facility | 2018-03-28 | Routine/Complete Inspection | No Violations Noted | Arrived at site at: 08:30. Weather: Overcast, cold ~ 35 degs. Onsite to perform routine inspections of wells on pad. A total of (9) wells were present on pad. All (9) wells were in production at time of inspection. All wells Prod. tree top press. "PTTP", Prod. line press. "PLP" and Prod. casing press. "PCP" were being monitored by wireless data sending units and/or analog gauges. (See individual well pressures and observations listed below.)
- All wells had (2) annular vents present labeled (13 3/8"x 9 5/8") and (9 5/8"x 5 1/2"). All annular vents were open and venting to (3) poly vent tanks "VTs" via shared 2" vent lines. I labeled the VTs with a black magic marker at time of inspection. (#1 VT shares the 2H, 5H, 3H & N1H annular vents. #2 VT shares the N4H, N2H & N3H annular vents. #3 VT shares the 1H & 4H annular vents.) I performed gas checks at VT lid openings using a Altair 5X gas meter calibrated on 3/5/18. Gas checks showed: VT #1 = 48% LEL, 2% CH4; VT #2 = 10% LEL, 0% CH4; VT #3 = 40% LEL, 2% CH4. |
2743697 | Primary Facility | 2018-06-12 | Routine/Complete Inspection | No Violations Noted | "Pump-down" operations were being conducted by Halliburton Oilfield Services on the 1H well. There were no violations noted. If you have any questions, please contact me. |
2804620 | Primary Facility | 2018-11-14 | Routine/Complete Inspection | No Violations Noted | Chief Oil & Gas submitted a Notice of Termination (NOT) for the Garrison pad covered under ESX29-131-17-0003. The NOT was received by the Department on 9/27/18. Arrived onsite for at 10:35; the weather was ~30°F and calm. Several frozen puddles were on the pad surface.
There were 9 properly tagged Marcellus wells staged for production. Most of the well cellars were filled with water; no bubbling was observed. There were 9 GPUs and 1 compressor onsite and in secondary containment. There was approx. 6 to 12 inches of mostly frozen water in the produced water tank secondary containment. Secondary containment also remained around the wells. I contacted Chris Vassallo via email and was informed on 11/16/18 that the containment is there due to scheduled maintenance on one of the wells. The site was well vegetated and appeared stable. All PCSM had been constructed and no temporary E&S BMPs remained. It is recommended that secondary containment around the produced water tanks be monitored and the water removed a |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2187919 | 674067 | 07/31/2013 | 2013-07-31 | 91.34A - Failure to take all necessary measures to prevent spill. Inadequate diking, potential pollution | Environmental Health & Safety | Release of small amount of Base Oil to ground as a result of faulty lining around tank. Contaminated soil was immediately excavated. Confirmatory sampling for thorough cleanup to follow. |
2187919 | 674068 | 07/31/2013 | 2013-07-31 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | Release of small amount of Base Oil to ground as a result of faulty lining around tank. Contaminated soil was immediately excavated. Confirmatory sampling for thorough cleanup to follow. |
For data sources see[9]