37-131-20363

Well Details

Well ID: 37-131-20363
Loading map...
Country: United States
State: Pennsylvania
County: Wyoming
Municipality: Tunkhannock Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 150328
Farm/Lease Name: ROBINSON ALBERT TR 1H
License Status: Plugged and Abandoned
Spud Date: 2014-01-11
Permit Date: 2013-10-31
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 41.581667
Longitude: -75.905944

For data sources see[1][2][3]

Well History

Date Event
2013-10-31 New Permit Application
2014-01-10 Performed Spud Operation
2014-02-09 Drilling Completion
2015-11-13 Inactive Well Request Granted
2015-12-01 NEWLY DRILLED
2018-07-02 Begin Plugging
2018-07-07 Finished Plugging
2018-08-17 Fully Plugged

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 SOUTHWESTERN ENERGY PROD CO 0.00 0 0.00 0 0.00 0
2015 SWN PROD CO LLC 0.00 0 0.00 0 0.00 0
2016 SWN PROD CO LLC 0.00 0 0.00 0 0.00 0
2017 SWN PROD CO LLC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 SOUTHWESTERN ENERGY PROD CO Drill Cuttings 1,806.73 Tons LANDFILL 101247
2018 SWN PROD CO LLC Other Oil & Gas Wastes 220.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Other Oil & Gas Wastes 330.00 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Synthetic Liner Materials 7.00 Tons LANDFILL 100933

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2223847 Primary Facility 2013-11-22 Preoperation Inspection No Violations Noted
2236146 Primary Facility 2014-01-14 Drilling/Alteration No Violations Noted 20" conductor set @ 40' on 1/11/2013, no one on site.
2239618 Primary Facility 2014-01-24 Drilling/Alteration No Violations Noted SDC 10, Comp Man - Brett Herbert, @ 55'
2241063 Primary Facility 2014-01-30 Drilling/Alteration No Violations Noted DDI 10, Comp Man - Brett Hebert, @ 1816'
2243435 Primary Facility 2014-02-06 Drilling/Alteration No Violations Noted SDC 10, Comp Man - Brett Hebert, @ 5989', Tripping back in w/ new bit.
2246428 Primary Facility 2014-02-19 Routine/Complete Inspection Pending Rig has moved out. Crew working on site clean-up. Doing a good job getting up snow and ice and hauling away. Cellar has been cleaned out. Did not receive cement job notifications for intermediate and production csg.
2365837 Primary Facility 2015-04-30 Routine/Complete Inspection No Violations Noted
2419586 Primary Facility 2015-10-26 Routine/Complete Inspection No Violations Noted
2604278 Primary Facility 2017-06-08 Routine/Partial Inspection Pending
2606158 Primary Facility 2017-06-21 Follow-up Inspection No Violations Noted This inspection is related to e-Facts Inspection ID: 2604278. The operator reported replacing the missing well label on 20JUN2017.
2740884 Primary Facility 2018-06-13 Routine/Complete Inspection No Violations Noted A routine (pre-plugging) inspection of this uncompleted vertical unconventional well was conducted May 13, 2018. A well record submitted with a Notice of Intent to plug this will indicates the well has surface and intermediate casing set, openhole to TD @ 8210' and partially plugged back to 6825'. At the time of inspection; no SWN personnel or equipment are on location. The casing head is on 9 5/8" casing (both valves shut in), spool with two wing valves on top, hanger, master valve and an analog pressure gauge (read 0 PSI). 13 3/8" surface casing and the conductor are both cut below grade in the cellar and visible. The cellar was full of water and there was no bubbling observed. No obvious issues were observed. Plugging was scheduled to take place yesterday, June 12th.
2749011 Primary Facility 2018-07-05 Plugging(Includes Plugged/Mined Through) No Violations Noted A workover rig is on location for plug and abandonment. The well has only surface/intermediate casings installed, never stimulated, and partially plugged back (top of bottomhole plug @ 6825' on well record). I met with the companyman and discussed operations on the pad. They tagged bottom @ 6728', circulated OBM out of the hole with gel. Cementers just left location after spotting final plug across the casing shoe (1963'-1663'). I took a lap around location. There was no visible or audible venting, discharging, or bubbling. No obvious issues were observed on location. The operator intends to tag plug tomorrow, top off with gravel, cut, mark, and bury the plugged well.
2752256 Primary Facility 2018-07-16 Plugging(Includes Plugged/Mined Through) No Violations Noted A routine inspection of this plugged well was conducted July 16, 2018. The rig is off location following plug and abandonment. At the time of inspection, the plugged well is cut, marked, and buried below ground level. There were no open holes, discharges, venting, or any obvious issues observed at the well location. No gas was detected with an Altair 5x gas meter in the gravel standing above the buried well.
2762968 Primary Facility 2018-08-13 Routine/Complete Inspection No Violations Noted The site is currently being restored. There was no activity occurring at the time of this inspection. There were no violations noted. If you have any questions, please contact me.
2845870 Primary Facility 2019-02-21 Site Restoration No Violations Noted I arrived onsite at 1530 to conduct a post-plugging site restoration inspection in response to a report received from the Operator. The weather was sunny and mild at approximately 45 degrees F with a slight breeze and no precipitation.

After performing a site inspection and reviewing the plan, I agree site conditions meet the post-plugging restoration requirements for this location denoted in the plan.

No violations were noted, please feel free to contact me with any questions.

2852603 Primary Facility 2019-03-08 Plugging(Includes Plugged/Mined Through) No Violations Noted A routine, post-plugging, follow-up inspection of this plugged unconventional well was conducted March 8, 2019. At the time of inspection, the site is reclaimed and the plugged well is cut and buried below grade in a field. The location was snow-covered. I stood at the buried well location; there were no open holes, discharges, bubbling, venting, staining, or other obvious issues observed.