37-131-20538

Well Details

Well ID: 37-131-20538
Loading map...
Country: United States
State: Pennsylvania
County: Wyoming
Municipality: Forkston Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 152119
Farm/Lease Name: OTTEN 3H
License Status:
Spud Date:
Permit Date: 2016-11-21
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.544411
Longitude: -76.144250

For data sources see[1][2][3]

Well History

Date Event
2016-11-21 New Permit Application
2017-02-18 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2017-05-06 2017-05-15 8,691 10,088,400 133,200

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FR-76 Halliburton Friction Reducer Listed Below
BE-9 Halliburton Biocide Listed Below
HAI-150E Halliburton Corrosion Inhibitor Listed Below
HYDROCHLORIC ACID Halliburton Solvent Listed Below
BE-9W Halliburton Biocide Listed Below
Acrylamide acrylate copolymer Proprietary 30 0.0250784 24596
Tributyl tetradecyl phosphonium chloride 81741-28-8 10 0.0036649 3595
Hydrochloric acid 7647-01-0 15 0.0805766 79026.5
Water 7732-18-5 100 85.6841 84,035,700.0
Neutralized Polyacrylic Emulsion Proprietary 10 0.00236579 2321
Inorganic salt Proprietary 30 0.0250784 24596
Water 7732-18-5 100 0.638178 625902
Non-hazardous food substance Proprietary 100 0.000349218 343
Crystalline silica, quartz 14808-60-7 100 13.6345 13,372,200.0
Hydrotreated light petroleum distillate 64742-47-8 30 0.0250784 24596
Propylene glycol 57-55-6 60 0.0123389 12102
Ethylene Glycol 107-21-1 60 0.0141947 13922
SAND-PREMIUM WHITE-30/50, BULK Halliburton Proppant Listed Below
Fresh Water Operator Base Fluid Listed Below
SAND-COMMON WHITE - 100 MESH, 3307 LB BAG Halliburton Proppant Listed Below
Ingredients Listed Above Listed Above Listed Below
LP-65 MC Halliburton Scale Inhibitor Listed Below

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2017 SWN PROD CO LLC 2,955,111.00 200 0.00 0 0.00 0
2018 SWN PROD CO LLC 2,957,853.00 346 0.00 0 0.00 0
2019 SWN PROD CO LLC 731,666.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2017 SWN PROD CO LLC Produced Fluid 5,195.33 Bbl SURFACE IMPOUNDMENT 826342
2017 SWN PROD CO LLC Other Oil & Gas Wastes 471.75 Bbl REUSE (AT WELL PAD)
2017 SWN PROD CO LLC Other Oil & Gas Wastes 115.00 Bbl INJECTION DISPOSAL WELL 34-119-28776
2017 SWN PROD CO LLC Produced Fluid 8,493.67 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Drilling Fluid Waste 1,445.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Unused Fracturing Fluid Waste 13.33 Tons LANDFILL THR029
2017 SWN PROD CO LLC Produced Fluid 39.72 Tons LANDFILL THR029
2017 SWN PROD CO LLC Produced Fluid 3.24 Tons LANDFILL 301358
2017 SWN PROD CO LLC Produced Fluid 111.67 Bbl REUSE (AT WELL PAD)
2017 SWN PROD CO LLC Drilling Fluid Waste 1,529.00 Bbl REUSE (AT WELL PAD)
2017 SWN PROD CO LLC Unused Fracturing Fluid Waste 259.66 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Other Oil & Gas Wastes 284.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Synthetic Liner Materials 5.39 Tons LANDFILL 100933
2017 SWN PROD CO LLC Produced Fluid 250.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 SWN PROD CO LLC Produced Fluid 1,684.66 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid 473.33 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Produced Fluid 550.34 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Other Oil & Gas Wastes 184.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Synthetic Liner Materials 8.33 Tons LANDFILL 101247
2019 SWN PROD CO LLC Produced Fluid 263.34 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Produced Fluid 73.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC035
2019 SWN PROD CO LLC Other Oil & Gas Wastes 14.17 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Spent Lubricant Waste 36.67 Bbl RESIDUAL WASTE TRANSFER FACILITY 101532
2019 SWN PROD CO LLC Produced Fluid 1,377.66 Bbl SURFACE IMPOUNDMENT 95-16-65420-013

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2563332 Primary Facility 2017-02-21 Drilling/Alteration No Violations Noted
2580166 Primary Facility 2017-04-04 Drilling/Alteration No Violations Noted
2581569 Primary Facility 2017-04-11 Drilling/Alteration No Violations Noted
2584134 Primary Facility 2017-04-11 Drilling/Alteration No Violations Noted
2584469 Primary Facility 2017-04-18 Drilling/Alteration No Violations Noted
2639888 Primary Facility 2017-09-26 Routine/Complete Inspection No Violations Noted Arrived on location at: 10:30. Weather: Clear, warm, ~ 75 degs. On location to perform routine inspection of wells on pad. This pad has a total of (3) wells on pad. All wells were in production at time of inspection. All wells were producing through tubing. Tubing production pressures were being monitored by wireless sending units with LED readouts. Tubing pressures were: 1H: 1170.6 psi., 2H: LED readout not working., 3H: 1169.9. Production line pressures were being monitored by "PCS High-Low" control panels. Prod. line pressures were: 1H: 1164 psi., 2H: 1162 psi., 3H: 1165 psi. All wells (9x5) annuli vents were plumbed to surface. These vents were SI. Taylor plugs were present for pressure checks using a crystal gauge. No gauges were present to check pressures at these annuli at time of inspection. (3) GPU units were present, one for each well. The Total Flow Control panel by GPUs was password protected and inaccessible at time of inspection. No obvious concerns were noted at wells or production units. (15)
2819653 Primary Facility 2019-03-12 Site Restoration No Violations Noted I arrived onsite at 1255 to conduct a site restoration inspection of the pad. I was accompanied by Jon Sassi (EPS-DEP).

While onsite, we observed staining on an unlabeled tank near the compressor facility that is reportedly used for oil associated with the compressor. The fluid in secondary containment had a foamy oily substance floating on top. The pad surface was also stained in the immediate vicinity of the tank. Mr. Sassi called Mike Deming (SWN) to notify him of the release. Mr. Deming stated that SWN had known about the release, and that it had occurred several days earlier but was not reported due to SWN's assertion that it was under 5 gallons. Operator, the Department requests that you inspect the area and begin remediation activities immediately. Additionally, please ensure all tanks are labeled with the name of the substance they contain as well as remove any standing fluid in the tank's containment.

Violations were noted during this inspection. Please contact me with any questions.

2836172 Primary Facility 2019-01-24 Routine/Complete Inspection No Violations Noted I arrived onsite at 1423 to perform a routine complete inspection of the pad. The weather was 36 degrees F with moderate snow beginning to accumulate, cloudy skies, and a steady moderate wind.

The lengthy access road appeared to be in good condition with no obvious areas of accelerated erosion and sedimentation. Pad was not plowed and most of the pad surface was covered in an icy slush.

I noticed that some areas of the access slope contained exposed erodible material on the steep fill slope, providing a potential source for accelerated erosion and sedimentation. Operator, please inspect the area and determine if they need to be reseeded/mulched when weather permits.

I also noted that the one (1) produced water tank located near the GPUs on the pad was not labeled. As I continued my inspection, I observed that there was another tank on the pad located next to the compressor facility that was also unlabeled. Operator, please inspect the area and determine what steps need to be taken to remedy the aforementi