34-103-23757

Well Details

Well ID: 34-103-23757
Loading map...
Country: United States
State: Ohio
County: Summit
Municipality: Bath Township
Operator Name: HYDROCARBON RESOURCES LTD
Well Pad ID:
Farm/Lease Name: LEIBY
License Status: Producing
License Date: 1984-08-02
Spud Date: 1984-09-07
Spud Drilling Contractor: G & H DRLG
Final Drill Date: 1984-09-11
Well Total Depth: 3744.00 ft
Configuration: Vertical
Latitude: 41.140000
Longitude: -81.680000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1984-08-02 1108 HYDROCARBON RESOURCES INC GeoDate 8/2/84
Oil and Gas 1984-08-02 Issued Date 8/2/84 Expired Date 1/29/85 Acres 0020000 Tool Type RTF Proposed Formation CLINTON Proposed Depth 03744 Proposed Drill Depth 03744
Original Spud 1984-09-07
Completed 1984-09-11
Reached Total Depth 1984-09-11
Completion Report Received 1984-10-31
Construction Permit Expires 1985-01-29
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3570 3648 0
3570 3648 0
2006-09-11 3597 3635 19
3597 3635 19
3570 3648 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 72000 Gal 25000 FRAC:H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2001 HYDROCARBON RESOURCES LTD 360.00 0.00 350
2002 HYDROCARBON RESOURCES LTD 842.00 78.00 340
2003 HYDROCARBON RESOURCES LTD 579.00 130.00 320
2004 HYDROCARBON RESOURCES LTD 573.00 58.00 326
2005 HYDROCARBON RESOURCES LTD 387.00 86.00 319
2006 HYDROCARBON RESOURCES LTD 525.00 73.00 324
2007 HYDROCARBON RESOURCES LTD 771.00 68.00 321
2008 HYDROCARBON RESOURCES LTD 538.00 82.00 340
2009 HYDROCARBON RESOURCES LTD 555.00 68.00 330
2010 HYDROCARBON RESOURCES LTD 558.00 66.00 330
2011 HYDROCARBON RESOURCES LTD 481.00 21.00 326
2012 HYDROCARBON RESOURCES LTD 378.00 57.00 318
2013 HYDROCARBON RESOURCES LTD 387.00 57.00 290
2014 HYDROCARBON RESOURCES LTD 420.00 19.00 293
2015 HYDROCARBON RESOURCES LTD 416.00 33.00 290
2016 HYDROCARBON RESOURCES LTD 354.00 43.00 268
2017 HYDROCARBON RESOURCES LTD 318.00 50.00 281
2018 HYDROCARBON RESOURCES LTD 268.00 48.00 273

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2001 HYDROCARBON RESOURCES LTD Brine 15 350
2002 HYDROCARBON RESOURCES LTD Brine 20 340
2003 HYDROCARBON RESOURCES LTD Brine 0 320
2004 HYDROCARBON RESOURCES LTD Brine 10 326
2005 HYDROCARBON RESOURCES LTD Brine 0 319
2006 HYDROCARBON RESOURCES LTD Brine 18 324
2007 HYDROCARBON RESOURCES LTD Brine 19 321
2008 HYDROCARBON RESOURCES LTD Brine 18 340
2009 HYDROCARBON RESOURCES LTD Brine 9 330
2010 HYDROCARBON RESOURCES LTD Brine 14 330
2011 HYDROCARBON RESOURCES LTD Brine 8 326
2012 HYDROCARBON RESOURCES LTD Brine 5 318
2013 HYDROCARBON RESOURCES LTD Brine 14 290
2014 HYDROCARBON RESOURCES LTD Brine 19 293
2015 HYDROCARBON RESOURCES LTD Brine 11 290
2016 HYDROCARBON RESOURCES LTD Brine 9 268
2017 HYDROCARBON RESOURCES LTD Brine 20 281
2018 HYDROCARBON RESOURCES LTD Brine 9 273

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1317943067 2013-4-10 0:00: PW No Violations 1.50
-1440150339 2013-10-22 0:00 PW No Violations
-1583471941 2014-6-23 0:00: PW No Violations
000PL11581 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
1317943067 2013-04-10 Production Wells No Violations I inspected this well and found one electric powered pump jack on the wellhead. The gauge on the tubing showed a pressure of 90 psi. and there was no gauge on the casing so I could not determine the pressure. A small well identification sign was posted on the electrical panel next to the pump jack. No leaks were seen on the wellhead or on the adjacent piping and the area around the well was nicely maintained. The tank battery contained four 100 bbl. steel oil storage tanks, two 50 bbl. steel brine storage tanks, one vertical oil and gas separator unit, one gas sales chart recorder and one drip assembly. It was determined that only one of the oil storage tanks was in operation and the other three were empty and disconnected from any piping. It was also determined that the two steel brine storage tanks were empty and not in operation and disconnected from any piping. The proper identififcation sign was posted on the operational tank and no leaks were seen on the tanks or piping within the tank battery. The dike was in good shape and the area within and around the dike was well maintained. It was determined that this tank battery also handles production for six other Leiby wells.
1440150339 2013-10-22 Production Wells Violations Noted Inspected production well on 10/22/2013. Wellhead is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead, but is barely legible. Tank battery consists of 4-210 bbl tanks, 2-50 bbl tanks, and a separator on a gravel pad within an earthen dike. Tank battery is used by multiple wells (as indicated by the well identification sign posted on it), but there is only one permit number listed on the identification sign. There is standing oil and contaminated soil and rock inside the tank battery, 1 of the 210-bbl tanks is tilted, and 3 of the 210-bbl tanks are leaking oil due to corrosion at the bottom of the tanks. Grass ~6-8 outside of diked area is oil-covered. Attempted to contact operator using emergency contact number listed on the tank battery and found that the number was no longer in service. Attempted to contact operator using contact number filed with the state; I left a message and have not yet heard back.
1583471941 2014-06-23 Production Wells No Violations Inspected production well on 06/23/2014. The tank battery consists of 2-100 bbl steel tank and 1-vertical separator located within an earthen dike. The tank battery is used by multiple wells; identification is clearly displayed for all wells utilizing it. All issues noted at the tank battery during the previous inspection have been addressed, and the well is back in compliance with the law. The well is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
1927999020 2015-07-27 Production Wells No Violations Inspected production well on 07/27/2015. The tank battery consists of 2-100 bbl steel tanks and 1-vertical separator located within an earthen dike. The tank battery is used by multiple wells (5); well identification is posted for all wells utilizing it. The well is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
PL11581 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1440150339 US-OH-112808 2013-12-02 Well operation causing pollution and contamination
1440150339 US-OH-112809 2013-12-02 Failure to legibly identify well

For data sources see[9]