Well Details

Well ID: 34-143-60235
Loading map...
Country: United States
State: Ohio
County: Sandusky
Municipality: Sandusky Township
Operator Name: EMERGENCY PLUGGING
Well Pad ID:
Farm/Lease Name: ROOT
License Status: Final Restoration
License Date: 2010-07-09
Spud Date:
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 41.370000
Longitude: -83.170000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2010-07-09 Proposed Formations:TRENTON, Issued Date:7/9/2010, Expired Date:7/8/2012 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
Well Added to System 2011-02-10 WELL WAS ADDED TO SYSTEM ON 2/10/2011 3:54:09 PM
Plugged by Orphan Well Program 2011-03-30 Plugged by Orphan Well Program
Plugged/Abandoned 2011-03-30 INSPECTED BY THOM DENKO 03/24/2010. WELL WAS LOCATED DUE TO RELEASE OF OIL INTO FIELD TILE AND DRAINAGE DITCH. WELL IS OPEN HOLE WITH 8" CONDUCTOR PIPE AND 6.25" SURFACE CASING, NO TUBING AND NO RODS. BASED ON NEARBY RECORDS WELL SHOULD BE ABOUT 1380' DEEP.

I&O CN 2010 04 009.

Construction Permit Expires 2012-07-08 INSPECTED BY THOM DENKO 03/24/2010. WELL WAS LOCATED DUE TO RELEASE OF OIL INTO FIELD TILE AND DRAINAGE DITCH. WELL IS OPEN HOLE WITH 8" CONDUCTOR PIPE AND 6.25" SURFACE CASING, NO TUBING AND NO RODS. BASED ON NEARBY RECORDS WELL SHOULD BE ABOUT 1380' DEEP.

I&O CN 2010 04 009.

Record Last Modified 2013-03-14 INSPECTED BY THOM DENKO 03/24/2010. WELL WAS LOCATED DUE TO RELEASE OF OIL INTO FIELD TILE AND DRAINAGE DITCH. WELL IS OPEN HOLE WITH 8" CONDUCTOR PIPE AND 6.25" SURFACE CASING, NO TUBING AND NO RODS. BASED ON NEARBY RECORDS WELL SHOULD BE ABOUT 1380' DEEP.

I&O CN 2010 04 009.

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1191277424 2011-3-21 0:00: PB No Violations
-192344203 2011-3-3 0:00:0 PB No Violations
-1962404527 2011-4-4 0:00:0 AM No Violations
0192344203 2011-03-03 Plug / Plug Back No Violations Toledo Edison place sleves on power lines for work on well.
0356336001 2011-05-26 Final Restoration No Violations Final restoration, equipment removed. Site graded. Lane restored and site clean.
1191277424 2011-03-21 Plug / Plug Back No Violations Plug well.
1375134258 2011-03-15 Plug / Plug Back No Violations Inspect well. Half of the tubing has been pulled. Work shut down due to rain and power lines next to well.
1705972725 2011-03-01 Plug / Plug Back No Violations Inspect well. Well located 15 feet from power lines.
1962404527 2011-04-04 Administrative Inspection No Violations Cement was tagged at 40 feet. Top off with cement.
2044620974 2010-03-24 Orphan No Violations Inspect well. Well added to database. Complete well includes 8 inch casing, 6.25 inch casing appears to be heavily rusted, 4.25 inch casing appears to have been installed as a liner to shut-off the fresh water, well head, 2 inch tubing, and rods, grass hopper pump jack. No shackle line or tanks present. Based on records for nearby wells, this should be about 1380 feet deep. The base of the limestone should be 385 feet below grade. Coordinates for well head are NAD 27:N41.37401 W83.17606.
356336001 2011-5-26 0:00: FR No Violations 0.00